 Install the nut (61) with the washer (62).

 (13)
 Tighten the nut (61) and safety it with a new cotter pin (60).


 5. Close-up
________ Subtask 52-22-12-865-061
 A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU EIS/SLIDES/ARM AND WARN/FLT 15WN P11 121VU EIS/SLIDES/ARM AND WARN/GND 13WN P10 121VU EIS/SDAC1 AND 2/DOOR/DET/PAX 48WV P05
 Subtask 52-22-12-410-053
 B. Close Access
 (1)
 Make sure that the work area is clean and clear of tool(s) and other items.

 (2)
 Do the special precaution on the door damper and emergency operation cylinder (Ref. TASK 52-22-00-860-004).

 (3)
 Close the emergency exit door (Ref. TASK 52-22-00-410-001).

 (4)
 Remove the access platform(s).


 1EFF : 301-399, 1 52-22-12Page 428 1 1 May 01/04 1 1 1CES 1


 CYLINDER - DOOR DAMPER AND EMERGENCY OPERATION - REMOVAL/INSTALLATION
_____________________________________________________________________ TASK 52-22-14-000-001 Removal of the Door Damper and Emergency Operation Cylinder
 1.
 Reason for the Job

__________________
 Self Explanatory


 2.
 Job Set-up Information


______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking caps
 No specific circuit breaker(s) safety clip(s)
 No specific access platform 3.2 m (10 ft. 6 in.)

 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
52-22-00-010-001  Opening of the Emergency Exit Doors from the Passenger Compartment 52-22-00-860-003 Special Precaution before Maintenance on the Door Damper and Emergency Operation Cylinder 52-22-14-991-001 Fig. 401
 3. Job Set-up
__________ Subtask 52-22-14-865-050
 A. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU COM/CIDS/DEU B/ESS 153RH G03
 1EFF : 301-399, 1 52-22-14Page 401 1 1 May 01/04 1 1 1CES 1 Subtask 52-22-14-010-050


 B. Get Access
 (1)
 Partly open the applicable emergency exit door (referred to as door) as required (Ref. TASK 52-22-00-010-001).

 (2)
 Make sure that the access platform is in position below the partly opened door.

 (3)
 Make sure that the special precaution procedure for the door damper and emergency operation cylinder is completed (Ref. TASK 52-22-00-860-003).


 4. Procedure
_________
 (Ref. Fig. 401/TASK 52-22-14-991-001)
 WARNING : BEFORE YOU START WORK ON THE DOOR MAKE SURE THAT: - THE SLIDE
_______ CONTROL HANDLE IS IN THE DISARMED POSITION WITH THE SAFETY PIN INSTALLED. - THE PERCUSSION LEVER OF THE DOOR DAMPER CYLINDER IS IN THE DISARMED POSITION WITH THE SAFETY PIN INSTALLED.
 Subtask 52-22-14-020-050
 A. Removal of the Door Damper and Emergency Operation Cylinder
 (1) Remove the electrical connections from the door damper and emergency operation cylinder (referred to as door damper) as follows:
 (a) Disconnect the applicable connector (22) from the related
 receptacle (24) (refer to the subsequent table): ---------------------------------------------------------| DOOR | CONNECTOR | DOOR DAMPER | FRAME | CABLE LOOM |
 _________________________________________________________
 | FWD LH | 360RH5-A  |  1600WM  |  FR35  |  4251VB  |
 | FWD RH | 360RH6-A  |  1601WM  |  FR35  |  4250VB  |
 | AFT LH | 360RH7-A  |  1602WM  | FR47.2 |  4253VB  |
 | AFT RH | 360RH8-A  |  1603WM  | FR47.2 |  4252VB  |

 ---------------------------------------------------------
(b)
 Put blanking caps on the disconnected electrical connectors.

 (c)
 Temporarily attach the cable loom to the support arm.


 (2) Remove the screw (13), the washer (12) and the bonding strap (11) from the door damper (1).
 
中国航空网 www.aero.cn