(2)
Do the special precaution on the door damper and emergency operation cylinder (Ref. TASK 52-22-00-860-003).
1EFF : 301-399, 1 52-22-11Page 612 1 1 May 01/05 1 1 1CES 1 1EFF : 301-399, 1 52-22-11Page 613 1 1 May 01/05 1 1 1CES 1
4. Procedure_________
Subtask 52-22-11-210-052
R A. Detailed Inspection of the Door Damper and Emergency Operation Cylinder
(1) Examine the the door damper and emergency operation cylinder (referred to as door damper) as follows:
R (a) Make sure that there is no fluid leakage around the door damper.
(b) Make sure that there are no corrosion, cracks, marks or dents on the door damper.
(c) Make sure that the door damper is correctly attached.
R (d) Make sure that the paint is in the correct condition.
R R (2) Examine the bonding straps of the door damper and their attachments for correct condition (Ref. TASK 20-28-00-912-001).
R (3) Make sure that the pressure of the door damper shown on the pressure gauge is correct.
R (4) If the pressure is not correct, charge the door damper (Ref. TASK 52-22-00-614-002).
5. Close-up________
Subtask 52-22-11-410-056
A. Close Access
(1) Make sure that the work area is clean and clear of tool(s) and other items.
(2) Do the special precaution on the door damper and emergency operation cylinder (Ref. TASK 52-22-00-860-004).
(3) Close the door correctly (Ref. TASK 52-22-00-410-001).
TASK 52-22-11-200-005 General Visual Inspection of Forward Emergency Exits, External Surface, LH/RH
1.
Reason for the Job
__________________
Refer to the MPD TASK: 522201-01
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific 1 ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
51-73-11-300-001 Repair of Minor Damage on Aluminum Clad Components 51-73-11-300-003 Repair of Dents in Skin Panels 51-75-12-300-001 Repair of Major Paint Damage on Light Alloy and
Composite Material 51-75-12-300-003 Repair of Minor Paint Damage (Topcoat Only) ASRM 51730000100 ASRM 52200000200 ASRM 52200010100 52-22-11-991-007 Fig. 602
3. Job Set-up
__________ Subtask 52-22-11-941-050
A. Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at the closed forward emergency exit 833 (843).
1EFF : 301-399, 1 52-22-11Page 614 1 1 May 01/04 1 1 1CES 1
4. Procedure
_________ (Ref. Fig. 602/TASK 52-22-11-991-007) Subtask 52-22-11-210-053
A. General Visual Inspection Procedure
(1)
Clean the component interface and/or the adjacent area.
(2)
Examine the external surface of the forward emergency exit for scratches and dents to the surface protection.
(a) If you find scratches, dents or other damage:
1 Find the dimensions of the damage and the allowable damage
_
limits (Ref. ASRM 52200010100).
a If you find damage that is less than the limit, remove it
_ (Ref. ASRM 51730000100) or (Ref. TASK 51-73-11-300-001) or (Ref. TASK 51-73-11-300-003).
b If you find damage to the surface protection only, repair
_ it (Ref. TASK 51-75-12-300-001) or (Ref. TASK 51-75-12-300-003), as necessary.
c If you find damage that is more than the limit, repair it
_
(Ref. ASRM 52200000200).
5. Close-up
________ Subtask 52-22-11-942-051
A. Remove the access platform(s).
1EFF : 301-399, 1 52-22-11Page 615 1 1 May 01/04 1 1 1CES 1
Forward Emergency-Exit External Surface
Figure 602/TASK 52-22-11-991-007
1EFF : 301-399, 1 52-22-11 Page 616
1 1 May 01/04
1 1
1CES 1
TASK 52-22-11-200-006
General Visual Inspection of Door Stop Assemblies and Locking Hook on Forward Emergency Exit Doors, LH/RH
1.
Reason for the Job
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM DOORS 舱门3(90)