R (e) Measure the clearance "J" between the adjustment washers (66) and
R the spacer tube (54).
R NOTE : A clearance of 0.05 mm (0.0019 in.) is permitted.____
R (f) Install the lower hinge pin (55), the washers (56) and the nut
R (59) to the lifting lever (57).
R (g) Tighten the nut (59) and safety it with the new cotter pin (60).
R 5. Close-up________
R Subtask 52-22-00-410-057
R A. Close Access
R (1) Remove the BALLAST WEIGHT - EMERGENCY EXIT from the door.
R (2) Make sure that the work area is clean and clear of tool(s) and other
R items.
R (3) Install the door linings (Ref. TASK 25-23-47-400-012) and (Ref. TASK
R 25-23-47-400-013) and the door frame linings (Ref. TASK 25-23-47-400-
R 004) and (Ref. TASK 25-23-47-400-009).
R (4) Do the special precaution on the door damper and emergency operation
R cylinder (Ref. TASK 52-22-00-860-004).
R (5) Close the door correctly (Ref. TASK 52-22-00-410-001).
R Subtask 52-22-00-865-055
R B. Make sure that this(these) circuit breaker(s) is(are) closed:
R 13WN, 15WN, 48WV
Adjustment of the Locking Mechanism
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific adjustment gage
R No specific Torque Wrench : range 0.00 to 1.20 m.daN
R (0.00 to 9.00 lbf.ft) 98D52207557000 1 BALLAST WEIGHT - EMERGENCY EXIT 98D52208282000 1 PIN - RIGGING, DOOR MECHANISM
B. Consumable Materials
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
No specific lockwire, corrosion resistance steel, dia 0.8 mm
(0.30 in.)
C. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
25-23-47-000-012 Removal of the Door Linings of the LH FWD Emergency Exit Door, zone 231
25-23-47-000-013 Removal of the Door Linings of the RH FWD Emergency Exit Door at zone 251 or RH AFT at zone 252 or LH AFT at zone 232.
25-23-47-400-012 Installation of the Door Linings of the LH FWD
Emergency Exit Door, zone 231
25-23-47-400-013 Installation of the Door Linings of the RH FWD Emergency Exit Door at zone 251, or RH AFT at zone 252, or LH AFT at zone 232.
1EFF : 301-399, 1 52-22-00Page 536 1 1 May 01/05 1 1 1CES 1 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R 52-22-00-010-001 R R 52-22-00-410-001 R R 52-22-00-710-001 R R R R 52-22-00-820-002 R 52-22-00-820-005 R 52-22-00-860-003 R R 52-22-00-860-004 R R 52-71-00-820-007 R R 52-22-00-991-013 R 52-22-00-991-014 R 52-22-00-991-015 R 52-22-00-991-018 R 52-22-00-991-016
R 3. Job Set-up
__________
R Subtask 52-22-00-010-064
中国航空网 www.aero.cn
航空翻译 www.aviation.cn