R -------------------------------------------------------------------------------R REFERENCE DESIGNATION R -------------------------------------------------------------------------------
R 25-23-47-000-012
R
R 25-23-47-000-013
R
R
R 25-23-47-400-012
R
R 25-23-47-400-013
R
R
R 25-24-41-000-001
R 25-24-41-400-001
R 52-22-00-010-001
R
R 52-22-00-410-001
R
R 52-22-00-720-001
R
R
R
R 52-22-00-860-003
R
R 52-22-00-860-004
R
R 52-71-00-820-009
R
R 52-22-00-991-021
R 52-22-00-991-023
R 52-22-00-991-029
R 3. Job Set-up__________
R Subtask 52-22-00-010-073
R A. Get Access
Removal of the Door Linings of the LH FWD Emergency Exit Door, zone 231 Removal of the Door Linings of the RH FWD Emergency Exit Door at zone 251 or RH AFT at zone 252 or LH AFT at zone 232. Installation of the Door Linings of the LH FWD Emergency Exit Door, zone 231 Installation of the Door Linings of the RH FWD Emergency Exit Door at zone 251, or RH AFT at zone 252, or LH AFT at zone 232. Removal of the Overhead Stowage Compartments Installation of the Overhead Stowage Compartments Opening of the Emergency Exit Doors from the Passenger Compartment Closing of the Emergency Exit Doors from the Passenger Compartment Check of Door Unlocking from Inside/Outside in Armed Position and of Slide Release Mechanism Arming/Disarming, Functional Check ofSlide Cable Movement Special Precaution before Maintenance on the Door Damper and Emergency Operation Cylinder Special Precaution after Maintenance on the Door Damper and Emergency Operation Cylinder Adjustment of the Proximity Switches (5WN1, 5WN2, 6WN1, 6WN2) of the Emergency Exits Fig. 516 Fig. 517 Fig. 518
R (1) Open the emergency exit door (referred to as door) (Ref. TASK 52-22-R 00-010-001).
R (2) Make sure that the special precaution on the door damper and
R emergency operation cylinder is done (Ref. TASK 52-22-00-860-003).
1EFF : 301-399, 1 52-22-00Page 553 1 1 May 01/04 1 1 1CES 1 1EFF : 301-399, 1 52-22-00Page 554 1 1 May 01/04 1 1 1CES 1
R Subtask 52-22-00-865-062
R B. Open, safety and tag this(these) circuit breaker(s):
R -------------------------------------------------------------------------------
R PANEL DESIGNATION IDENT. LOCATION
R -------------------------------------------------------------------------------
R 121VU EIS/SLIDES/ARM AND WARN/FLT 15WN P11
R 121VU EIS/SLIDES/ARM AND WARN/GND 13WN P10
R 121VU EIS/SDAC1 AND 2/DOOR/DET/PAX 48WV P05
R Subtask 52-22-00-860-074
R C. Aircraft Maintenance Configuration
R (1) Remove the door linings as required (Ref. TASK 25-23-47-000-012) and
R (Ref. TASK 25-23-47-000-013).
R (2) Install the BALLAST WEIGHT - EMERGENCY EXIT (98D52207557000) to the
R emergency exit door (referred to as door) to replace the weight of
R the door linnigs during the adjustment procedure.
R (3) Make sure that the door is closed and the slide control handle is in
R the armend position (Ref. TASK 52-22-00-410-001).
R (4) Remove the overhead stowage compartments above the applicable door