R **ON A/C 106-149, 301-399, 401-499,
 122VU AIR COND/CIDS/SDF/DIR NORM/2 14WH T18
 122VU AIR COND/CIDS/SDF/DIR NORM/1 17WH T17
 **ON A/C 301-399,
 Subtask 23-73-00-865-205
 C. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
 -------------------------------------------------------------------------------
2001VU CIDS/DEU A NORM/ MID/ LH 197RH C04
 2001VU CIDS/DEU A NORM/ MID/ RH 198RH C05
 2001VU CIDS/DEU A NORM/ AFT/ LH 173RH C06
 2001VU CIDS/DEU A NORM/ AFT/ RH 174RH C07
 2001VU CIDS/DEU B NORM/ AFT 194RH C08 
R 1EFF : 106-149, 301-399, 401-499, 1 23-73-00Page C577 1 1 Aug 01/05 1 1 1CES 1R **ON A/C 106-149, 301-399, 401-499,
 4. Procedure
_________
 **ON A/C 301-399,
 Subtask 23-73-00-710-310
 A. Do the Test of the EVAC Signalling System
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. In the cockpit, on the overhead panel 21VU:
 -switch the EVAC/CAPT&PURS/CAPT switch to the CAPT&PURS position.
 2. In the cockpit, on the overhead panel 21VU: 
-lift the guard and push the EVAC COMMAND pushbutton switch. 
In the cockpit, on the overhead panel21VU:
-
the EVAC indicator light in the EVACCOMMAND pushbutton switch flashes.
 -
the ON indicator light in the COMMAND pushbutton switch comes on.
On the Flight Attendant Panel (FAP):
 -
the integral light in the EVAC / RESET pushbutton switch flashes.
On the AFT Attendant Panel (AAP):
 -
the EVAC indicator light flashes.
At the MID attendant station on the EVAC Indication and EVAC/SMOKE RESET Panel 2064VU:
 -
the EVAC indicator light flashes.
R 1EFF : 106-149, 301-399, 401-499, 1 23-73-00Page C578 1 1 Aug 01/05 1 1 1CES 1
 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
3. On the Flight Attendant Panel (FAP):
 -push the EVAC / RESET 
pushbutton switch.
4. On the AFT Attendant Panel (AAP): 
-push the EVAC / RESET 
pushbutton switch.
At the EXIT attendant station on the EVAC Indication abd EVAC/SMOKE RESET Panel 2064VU:
 -
the EVAC indicator light flashes.
On all Attendant Indication Panels (AIPs):
 -
the pink indicator light flashes.
 -
the message EVACUATION ALERT comes on.
Through the loudspeakers at all attendant stations:
 -
the EVAC signal is heard.On the FWD AIP:
-
the message EVACUATION ALERT goesoff.
 -
the pink indicator goes off.
Through the loudspeakers at the FWD attendant station:
 -
the EVAC signal goes off.On the AFT AIPs:
-
the message EVACUATION ALERT goesoff.
 -
the pink indicator goes off.
Through the loudspeakers at the AFT attendant stations:
 -
the EVAC signal goes off.
R 1EFF : 301-399, 1 23-73-00Page C579 1 1 Aug 01/05 1 1 1CES 1
 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
5. At the MID attendant station on the EVAC Indication and EVAC/SMOKE RESET Panel 2064VU:
 -push the RESET pushbutton switch. 
6. At the EXIT attendant station on the EVAC Indication and EVAC/SMOKE RESET Panel 2064VU:
 -push the RESET pushbutton switch. 
7. In the cockpit, on the overhead panel 21VU: 
-lift the guard and push the EVAC COMMAND pushbutton switch to reset it.
On the MID AIP:
-
the message EVACUATION ALERT goesoff.
 -
the pink indicator goes off.
Through the loudspeakers at the MID attendant station:
 -
the EVAC signal goes off.On the EXIT AIP:
-
the message EVACUATION ALERT goesoff.
 -
the pink indicator goes off.
Through the loudspeakers at the EXIT attendant station:
 -
the EVAC signal goes off.
In the cockpit, on the overhead panel21VU:
-
the EVAC indicator light in the EVACCOMMAND pushbutton switch goes off.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM Communications 通讯4(76)