1EFF : 301-399, 1 23-73-00Page C569 1 1 Aug 01/05R 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
3. On the Flight Attendant Panel (FAP):
-push the EVAC / RESET
pushbutton switch.
4. On the AFT Attendant Panel (AAP):
-push the EVAC / RESET
pushbutton switch.
5. At the MID attendant station on the EVAC Indication and EVAC/SMOKE RESET Panel 2064VU:
-push the RESET pushbutton
switch.
On all Attendant Indication Panels (AIPs):
-
the pink indicator light flashes.
-
the message EVACUATION ALERT comes on.
Through the loudspeakers at all attendant stations:
-
the EVAC signal is heard.On the FWD AIP:
-
the message EVACUATION ALERT goesoff.
-
the pink indicator goes off.
Through the loudspeakers at the FWD attendant station:
-
the EVAC signal goes off.On the AFT AIPs:
-
the message EVACUATION ALERT goesoff.
-
the pink indicator goes off.
Through the loudspeakers at the AFT attendant stations:
-
the EVAC signal goes off.On the MID AIP:
-
the message EVACUATION ALERT goesoff.
1EFF : 301-399, 1 23-73-00Page C570 1 1 Aug 01/05R 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-the pink indicator goes off.
6. At the EXIT attendant station on the EVAC Indication and EVAC/SMOKE RESET Panel 2064VU:
-push the RESET pushbutton switch.
7. In the cockpit, on the overhead panel 21VU:
-lift the guard and push the EVAC COMMAND pushbutton switch to reset it.
Through the loudspeakers at the MID attendant station:
-
the EVAC signal goes off.On the EXIT AIP:
-
the message EVACUATION ALERT goesoff.
-
the pink indicator goes off.
Through the loudspeakers at the EXIT attendant station:
-
the EVAC signal goes off.
In the cockpit, on the overhead panel21VU:
-
the EVAC indicator light in the EVACCOMMAND pushbutton switch goes off.
-
the ON indicator light in the EVAC COMMAND pushbutton switch goes off.
On the Flight Attendant Panel (FAP):
-
the EVAC indicator light goes off. On the AFT Attendant Panel (AAP):
-
the EVAC indicator light goes off.
At the MID attendant station on the EVAC Indicator and EVAC/SMOKE RESET Panel 2064VU:
-
the EVAC indicator light goes off.
R 1EFF : 301-399, 1 23-73-00Page C571 1 1 Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
8. On the Flight Attendant Panel (FAP):
-push the EVAC CMD pushbutton switch.
In the cockpit on the overhead panel 21VU:
At the EXIT attendant station on the EVAC Indicator and EVAC/SMOKE RESET RESET Panel 2064VU:
-
the EVAC indicator light goes off.On the Flight Attendant Panel (FAP):
-
the integral light in the EVAC CMDpushbutton switch comes on.
-
the integral light in the EVAC / RESET pushbutton switch flashes.
On the AFT Attendant Panel (AAP):
-
the EVAC indicator light flashes.
At the MID attendant station on the EVAC Indicator and EVAC/SMOKE RESET Panel 2064VU:
-
the EVAC indicator light flashes.
At the EXIT attendant station on the EVAC Indicator and EVAC/SMOKE RESET Panel 2064VU:
-
the EVAC indicator light flashes.
In the cockpit, on the overhead panel 21VU:
-
the EVAC indicator light in the EVAC COMMAND pushbutton switch comes on.
In the cockpit:
-
the EVAC signal is heard.
R 1EFF : 301-399, 1 23-73-00Page C572 1 1 Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-push the HORN SHUT OFF pushbutton switch.
9. On the Flight Attendant Panel (FAP):
-push the EVAC CMD pushbutton switch to reset it.
10. In the cockpit, on the overhead panel 21VU:
-set the EVAC/CAPT&PURS/CAPT switch to the CAPT position.
11. On the Flight Attendant Panel (FAP):
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM Communications 通讯4(74)