R 1EFF : 051-099, 1 23-73-00Page C561 1 1 Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
- the EVAC horn gives an intermittant signal.
From all cabin and all attendant loudspeakers:
- the EVAC sound is heard as an intermittant signal.
- push to reset the EVAC COMD pushbutton. All messages are cancelled.
6. On the overhead panel 21VU:
- switch the EVAC CAPT PURS/CAPT switch to the CAPT position.
7. On the FAP 120RH: On the FAP 120RH:
- push the EVAC COMD pushbutton switch. - the COMD indicator light in the EVACCOMD pushbutton switch comes on.
On the overhead panel 21VU:
- the EVAC indicator light in the COMMAND pushbutton switch flashes.
On the overhead panel 48VU:
- the EVAC horn gives an intermittant signal for approx. 3 s.
- push to reset the EVAC COMD pushbutton switch. All messages are cancelled.
R 1EFF : 051-099, 1 23-73-00Page C562 1 1 Aug 01/05 1 1 1CES 1
R **ON A/C 151-199, 211-299,
Subtask 23-73-00-710-171-A
A. Do this test.
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the overhead panel 21VU:
- switch the EVAC CAPT PURS/CAPT switch to the CAPT PURS position.
On the overhead panel 21VU:
- push the EVAC COMMAND pushbutton switch. - the EVAC indicator light in theCOMMAND pushbutton switch flashes.
- the ON indicator light in the COMMAND pushbutton switch comes on.
On the overhead panel 48VU:
- the EVAC horn gives an intermittant signal.
On the Forward Attendant Panel (FAP) 120RH and the AFT Attendant Panel (AAP) 126RH:
- the EVAC indicator lights flash.
From the FWD and AFT attendant loudspeakers:
- the EVAC sound is heard as an intermittant signal.
- push to reset the EVAC COMMAND pushbutton switch. All messages are cancelled.
- push the EVAC COMMAND pushbutton switch. All cancelled messages come on again.
R 1EFF : 151-199, 211-299, 1 23-73-00Page C563 1 1 Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
On the overhead panel 48VU:
- push the EVAC HORN SHUT OFF pushbutton switch. - the EVAC sound stops.
2. On the FAP 120RH: From the FWD attendant loudspeakers:
- push the EVAC RESET pushbutton switch. - the EVAC sound stops.
3. On the AAP 126RH: From the AFT attendant loudspeakers:
- push the RESET pushbutton switch. - the EVAC sound stops.
4. On the overhead panel 21VU: On the overhead panel 21VU:
- push to reset the EVAC COMMAND pushbutton switch. - the EVAC and the ON indicator lightsin the COMMAND pushbutton switch go off.
On the FAP 120RH and the AAP 126RH:
- the EVAC indicator lights go off.
5. On the FAP 120RH: On the FAP 120RH:
- push the EVAC COMD pushbutton switch. - the COMD indicator light in the EVACCOMD pushbutton switch comes on.
- the EVAC indicator light flashes.
On the AAP 126RH:
- the EVAC indicator light flashes.
On the overhead panel 21VU:
- the EVAC indicator light in the COMMAND pushbutton switch flashes.
On the overhead panel 48VU:
R 1EFF : 151-199, 211-299, 1 23-73-00Page C564 1 1 Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
- the EVAC horn gives an intermittant signal.
From the FWD and AFT attendant loudspeakers:
- the EVAC sound is heard as an intermittant signal.
- push to reset the EVAC COMD pushbutton. All messages are cancelled.
6. On the overhead panel 21VU:
- switch the EVAC CAPT PURS/CAPT switch to the CAPT position.
7. On the FAP 120RH: On the FAP 120RH:
- push the EVAC COMD pushbutton switch. - the COMD indicator light in the EVACCOMD pushbutton switch comes on.