3. Job Set-up
__________
 **ON A/C 106-149,
 Subtask 23-73-42-860-050-B
 A. Aircraft Maintenance Configuration
 (1)
 Make sure that the aircraft electrical circuits are energized (Ref. TASK 24-42-00-861-001)
 (2)
 Make sure that the STEPLADDER 0.5 M (1.6 FT) is below the related access panel.
 (3)
 Make sure that the forward utility area - ceiling panel is removed:
-FOR 308RH1, 308RH2 remove 221BC and 222BC (Ref. TASK 25-23-42-000-001).
 (4)
 Make sure that the related cove light panels are removed:
 -
FOR 208RH1, 208RH2 remove 231JW and 232JW (Ref. TASK 25-23-48-000-001).
 -
FOR 208RH3, 208RH4 remove 231WW and 232WW (Ref. TASK 25-23-48-000-001).
 -
FOR 208RH7, 208RH8 remove 241QW and 242QW (Ref. TASK 25-23-48-000-001).
 -
FOR 308RH5, 308RH6 remove 241WW and 242WW (Ref. TASK 25-23-48-000-001).
 -
FOR 208RH11, 208RH12 remove 251FW and 252FW (Ref. TASK 25-23-48-000-001).
 -
FOR 208RH13, 208RH14 remove 251TW and 252TW (Ref. TASK 25-23-48-000-001).
 **ON A/C 301-399,
 Subtask 23-73-42-860-050-A
 A. Aircraft Maintenance Configuration
 (1)
 Make sure that the aircraft electrical circuits are energized (Ref. TASK 24-42-00-861-001)
 (2)
 Make sure that the STEPLADDER 0.5 M (1.6 FT) is below the related access panel.
R 1EFF : 106-149, 301-399, 401-499, 1 23-73-42Page 414 1 1 Aug 01/05 1 1 1CES 1
 (3) Make sure that the forward utility area - ceiling panel is removed: - FOR 308RH1, 308RH2 remove 221BC and 222BC (Ref. TASK 25-23-42-000-001). 
 (4) Make sure that the related cove light and ceiling panels are removed: - FOR 208RH1, 208RH2 remove 231JW and 232JW (Ref. TASK 25-23-48-000-001). - FOR 208RH3, 208RH4 remove 231WW and 232WW (Ref. TASK 25-23-48-000-001). - FOR 308RH3, 308RH4 remove 231JC (Ref. TASK 25-23-41-000-001). - FOR 208RH5, 208RH6 remove 231LC (Ref. TASK 25-23-41-000-001). - FOR 208RH7, 208RH8 remove 231XX and 232XX (Ref. TASK 25-23-48-000-001). - FOR 208RH9, 208RH10 remove 241WW and 242WW (Ref. TASK 25-23-48-000-001). - FOR 308RH5, 308RH6 remove 251KC (Ref. TASK 25-23-41-000-001). - FOR 208RH11, 208RH12 remove 251MC (Ref. TASK 25-23-41-000-001). - FOR 208RH13, 208RH14 remove 251QW and 252QW (Ref. TASK 25-23-48-000-001).  
R  **ON A/C 401-499,  
R  Subtask 23-73-42-860-050-C  
R  A. Aircraft Maintenance Configuration  
R R  (1) Make sure that the aircraft electrical circuits are energized (Ref. TASK 24-42-00-861-001)  
R R  (2) Make sure that the STEPLADDER 0.5 M (1.6 FT) is below the related access panel.  
R R R  (3) Make sure that the forward utility area - ceiling panel is removed: - FOR 308RH1, 308RH2 remove 221BC and 222BC (Ref. TASK 25-23-42-000-001).  
R R R R R R  (4) Make sure that the related cove light panels are removed: - FOR 208RH1, 208RH2 remove 231JW and 232JW (Ref. TASK 25-23-48-000-001). - FOR 208RH3, 208RH4 remove 231WW and 232WW (Ref. TASK 25-23-48-000-001). - FOR 208RH7, 208RH8 
R 1EFF : 301-399, 401-499, 1 23-73-42Page 415 1 1 Aug 01/05 1 1 1CES 1
R R R R R R R  remove 231ZW and 232ZW (Ref. TASK 25-23-48-000-001). - FOR 308RH5, 308RH6 remove 241TW and 242TW (Ref. TASK 25-23-48-000-001). - FOR 208RH11, 208RH12 remove 251WW and 252WW (Ref. TASK 25-23-48-000-001). - FOR 208RH13, 208RH14 remove 251TW and 252TW (Ref. TASK 25-23-48-000-001).  
R  **ON A/C 106-149, 301-399, 401-499, 
 Subtask 23-73-42-865-051 
 B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged 
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU AIR COND/CIDS/SDF/DIR2 ESS 18WH C06 49VU AIR COND/CIDS/SDF/DIR1 ESS 15WH C05  
 