3. Job Set-up
__________
Subtask 23-73-34-865-051
A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------FOR 101RH
**ON A/C 001-049, 051-099, 101-105, 201-299,
49VU COM/CIDS/DIR 1 AND 2/ESS 150RH G02 R **ON A/C 106-149, 301-399, 401-499,
49VU AIR COND/CIDS/SDF/DIR1 ESS 15WH C05 R **ON A/C 106-149, 151-199, 301-399, 401-499,
49VU COM DIR ESS/1 150RH G01 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
121VU COM NAV/CIDS/DIR 1 AND 2/NORM 151RH M05 **ON A/C 301-399,
121VU COM NAV/CIDS/DIR NORM/1 151RH M06 R **ON A/C 106-149, 301-399, 401-499,
122VU AIR COND/CIDS/SDF/DIR NORM/1 17WH T17 **ON A/C ALL
FOR 102RH
1EFF : ALL 1 23-73-34Page 407 1 1 Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------**ON A/C 001-049, 051-099, 101-105, 201-299,
R 49VU COM/CIDS/DIR 1 AND 2/ESS **ON A/C 106-149, 301-399, 401-499, 150RH G02
R 49VU AIR COND/CIDS/SDF/DIR2 ESS **ON A/C 106-149, 401-499, 18WH C06
R 49VU COM/CIDS/DIR ESS/2 **ON A/C 106-149, 151-199, 301-399, 401-499, 157RH G02
49VU COM DIR ESS/1 **ON A/C 151-199, 301-399, 150RH G01
49VU COM DIR ESS/2 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 157RH G02
R 121VU COM NAV/CIDS/DIR 1 AND 2/NORM **ON A/C 106-149, 151-199, 401-499, 151RH M05
121VU COM NAV/CIDS/DIR NORM/2 **ON A/C 301-399, 156RH M06
121VU COM NAV/CIDS/DIR NORM/2 121VU COM NAV/CIDS/DIR NORM/1 156RH 151RH M07M06
1EFF : ALL 1 23-73-34Page 408 1 1 Aug 01/05 1 1 1CES 1 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
R **ON A/C 106-149, 301-399, 401-499,
122VU AIR COND/CIDS/SDF/DIR NORM/2 14WH T18 **ON A/C ALL
4. Procedure
_________
**ON A/C 001-049, 051-099, 101-105, 201-299,
Subtask 23-73-34-420-050
A. Installation of the CIDS Directors NOTE : The installation procedures of the two CIDS Directors are not the
____
same.
(1)
Installation of the CIDS Director 1
(a)
Clean the component interface and/or the adjacent area.
(b)
Do an inspection of the component interface and/or the adjacent area.
(c)
Remove the blanking caps from the electrical connectors (1).
(d)
Make sure that the electrical connectors (1) are clean and in the correct condition.
(e)
Install the CIDS director 1(5) on its rack (2).
(f)
Push the CIDS director 1(5) on its rack (2) to connect the electrical connectors (1).
(g)
Engage the nuts (3) on the lugs (4) and tighten.
(2)
Installation of the CIDS Director 2
(a)
Remove the CIDS Director 1 (101RH) (Ref. TASK 23-73-34-000-001).
(b)
Clean the component interface and/or the adjacent area.
1EFF : ALL 1 23-73-34Page 409 1 1 Aug 01/05 1 1 1CES 1
(c)
Do an inspection of the component interface and/or the adjacent area.
(d)
Remove the blanking caps from the electrical connectors (1).
(e)
Make sure that the electrical connectors (1) are clean and in the correct condition.