-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
121VU COM NAV/CIDS/DEU A NORM/L AFT 167RH M12 121VU COM NAV/CIDS/DEU A NORM/R MID 166RH M11 121VU COM NAV/CIDS/DEU A NORM/L MID 165RH M10 121VU COM NAV/CIDS/DEU A NORM/R FWD 164RH M09 121VU COM NAV/CIDS/DEU A NORM/L FWD 163RH M08
R **ON A/C 106-149, 401-499,
121VU COM NAV/CIDS/DEU A NORM/R AFT 168RH M12
121VU COM NAV/CIDS/DEU A NORM/L AFT 167RH M11
R **ON A/C 106-149, 151-199, 401-499,
121VU COM NAV/CIDS/DEU A NORM/R FWD 164RH M10
121VU COM NAV/CIDS/DEU A NORM/L FWD 163RH M09
**ON A/C 151-199,
121VU COM NAV/CIDS/DEU A NORM/R AFT 168RH M14 121VU COM NAV/CIDS/DEU A NORM/L AFT 167RH M13 121VU COM NAV/CIDS/DEU A NORM/R MID 166RH M12 121VU COM NAV/CIDS/DEU A NORM/L MID 165RH M11
**ON A/C 301-399,
121VU COM NAV/CIDS/DEU A NORM/R FWD 164RH M11
121VU COM NAV/CIDS/DEU A NORM/L FWD 163RH M10
Subtask 23-73-63-865-070
C. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2001VU CIDS/DEU A NORM/ MID/ LH 197RH C04
2001VU CIDS/DEU A NORM/ MID/ RH 198RH C05
2001VU CIDS/DEU A NORM/ AFT/ LH 173RH C06
2001VU CIDS/DEU A NORM/ AFT/ RH 174RH C07
1EFF : ALL 1 23-73-63Page 413 1 1 Aug 01/05 1 1 1CES 1 **ON A/C ALL
4. Procedure
_________
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
(Ref. Fig. 401/TASK 23-73-63-991-001) R **ON A/C 106-149, 301-399, 401-499,
(Ref. Fig. 401A/TASK 23-73-63-991-001-A)
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
Subtask 23-73-63-420-050
A. Installation of the No Smoking/Fasten Seat Belt sign (NS/FSB)
(1) Installation of the NS/FSB with bulbs of the PSIU
(a)
Clean the component interface and/or the adjacent area.
(b)
Do an inspection of the component interface and/or the adjacent area.
(c)
Connect the electrical connector (8) as identified during the removal procedure.
(d)
Install the NS/FSB sign (7) into the related PSIU (3). NOTE : Make sure that you hear a click when the spring clips (6)
____
locks in position.
(e)
Install the lens (5) and make sure that the spring clips (4) locks into position with a click.
(f)
Make sure that the work area is clean and clear of tool(s) and other items.
(g)
Lift the PSIU (3) and engage it in the mounting rail (2).
(h)
Install the section-hose (1) with the PULLEY ASSEMBLY - SEALING CORD to the mounting rail (2).
1EFF : ALL 1 23-73-63Page 414 1 1 Aug 01/05 1 1 1CES 1
(2)
Installation of the NS/FSB with LED's of the PSIU
(a)
Clean the component interface and/or the adjacent area.
(b)
Do an inspection of the component interface and/or the adjacent area.
(c)
Connect the electrical connector (11) as identified during the removal procedure.
(d)
Install the NS/FSB (10) into the related PSIU (3).
(e)
Make sure that the spring clips (9) locks into position with a click.
(f)
Make sure that the work area is clean and clear of tool(s) and other items.
(g)
Lift the PSIU (3) and engage it in the mounting rail (2).
(h)
Install the section-hose (1) with the PULLEY ASSEMBLY - SEALING CORD to the mounting rail (2).
(3)
Insallation of the NS/FSB with bulbs of the C/B panel 2000VU and 2001VU
(a)
Clean the component interface and/or the adjacent area.
(b)
Do an inspection of the component interface and/or the adjacent area.
(c)
Connect the electrical connector (16) as identify during the removal procedure.
(d)
Install the NS/FSB sign (15) into the related circuit breaker panel (21).
NOTE : Make sure that you hear a click , when the spring clips
____ (14) locks in position.
(e)
Install the lens (13) and make sure that the spring clips (12) locks into position with a click.
(f)
Make sure that the work area is clean and clear of tool(s) and other items.