R 1EFF : 106-149, 301-399, 401-499, 1 23-73-00Page 33 1 1 Config-2 Aug 01/05 1 1 1CES 1
R **ON A/C 106-149, 301-399, 401-499,
(2) Decoder/Encoder Unit (DEU) type A
R **ON A/C 106-149, 401-499,
(Ref. Fig. 014)
**ON A/C 301-399,
(Ref. Fig. 014A)
R **ON A/C 106-149, 301-399, 401-499,
R R R R R (Ref. Fig. 015) Each DEU type A is controlled by the active director. The DEUs type A are connected to one of the two data bus top lines via connection boxes. One top line is installed along each A/C side. Every DEU type A on one A/C side is connected to the same top line. Every connection box includes coding switches which give each DEU type A its own address. The last connection box, connected to a top line, includes also a termination resistor for impedance matching and is therefore called a termination box.
R (a) The DEU type A has direct interfaces to the: - Director, - Passenger Interface and Supply Adapters (PISA), - Stand Alone Passenger Interface and Supply Adapters (StA PISA) (Ref. 33-27-00), - Ballast units, - Loudspeakers, - NS, FSB and RTS signs.
R R R (b) The DEU type A has interfaces via PISA or StA PISA to the: - Loudspeakers, - Reading lights, - Attendant work lights, - Seatrow identifiers, - Passenger call/reset pushbuttons, - Passenger call lights, - NS, FSB and RTS signs.
R 1EFF : 106-149, 301-399, 401-499, 1 23-73-00Page 34 1 1 Config-2 Aug 01/05 1 1 1CES 1
CIDS DATA BUS - Top Line Left and Right
Figure 014
R 1EFF : 106-149, 401-499, 1 23-73-00Page 35 1 1 Config-2 Aug 01/05 1 1 1CES 1
CIDS DATA BUS - Top Line Left and Right
Figure 014A
R 1EFF : 301-399, 1 23-73-00Page 36 1 1 Config-2 Aug 01/05 1 1 1CES 1
DEU type A Interfaces - Block Diagram
Figure 015
R 1EFF : 106-149, 301-399, 401-499, 1 23-73-00Page 37 1 1 Config-2 Aug 01/05 1 1 1CES 1
(3) Decoder/Encoder Unit (DEU) type B
R **ON A/C 106-149, 401-499,
(Ref. Fig. 016)
**ON A/C 301-399,
(Ref. Fig. 016A)
R **ON A/C 106-149, 401-499,
(Ref. Fig. 017)
**ON A/C 301-399,
(Ref. Fig. 017A)
R **ON A/C 106-149, 301-399, 401-499,
R R R R R Each DEU type B is controlled by the active director. The DEUs type B are connected to one of the two data bus middle lines through connection boxes. The middle lines are installed along each A/C side. The middle line at one A/C side (left and right) connects every DEU type B on the same side of the A/C. Every connection box includes coding switches which give each DEU type B its own address. The last connection box connected to a middle line includes also a termination resistor for impedance matching and is therefore called termination box.
R (a) The DEU type B has data bus interfaces to the: - Director, - Additional Attendant Panel (AAP), - Attendant Indication Panel (AIP), - Emergency Power Supply Unit (EPSU), - Lavatory smoke detector.
R 1EFF : 106-149, 301-399, 401-499, 1 23-73-00Page 38 1 1 Config-2 Aug 01/05 1 1 1CES 1
CIDS DATA BUS - Middle Line
Figure 016
R 1EFF : 106-149, 401-499, 1 23-73-00Page 39 1 1 Config-2 Aug 01/05 1 1 1CES 1
CIDS DATA BUS - Middle Line
Figure 016A
R 1EFF : 301-399, 1 23-73-00Page 40 1 1 Config-2 Aug 01/05 1 1 1CES 1
DEU type B Interfaces - Block Diagram
Figure 017
R 1EFF : 106-149, 401-499, 1 23-73-00Page 41 1 1 Config-2 Aug 01/05 1 1 1CES 1
DEU type B Interfaces - Block Diagram
Figure 017A
R 1EFF : 301-399, 1 23-73-00Page 42 1 1 Config-2 Aug 01/05 1 1 1CES 1
R **ON A/C 106-149, 401-499,
R R R R R R R (b) The DEU type B has discrete interfaces to the: - Area Call Panel (ACP), - Door pressure sensor, - Slide pressure sensor, - Drain Mast Control Unit (DMCU), - Waste service panel, - Vacuum generator, - Fan phase off relay, - Water service panel, - Prime level indicator (Precharge), - Vacuum power control relay, - Liquid Level Transmitter (LLT), - Liquid Level Sensor (LLS), - Flush Control Unit (FCU).
**ON A/C 301-399,
R R R R R R R R (b) The DEU type B has discrete interfaces to the: - Area Call Panel (ACP), - Door pressure sensor, - Slide pressure sensor, - EVAC/SMOKE reset panel - Drain Mast Control Unit (DMCU), - Waste service panel, - Vacuum generator, - Fan phase off relay, - Water service panel, - Prime level indicator (Precharge), - Vacuum power control relay, - Liquid Level Transmitter (LLT), - Liquid Level Sensor (LLS), - Flush Control Unit (FCU).