(b)
DEU A Power-Up Tests These are tested at this stage
1 Discrete outputs
_
-All discrete outputs are switched to the passive state. Then each output is activated separately and looped back to the DEU gate array and measured. All the discrete outputs are then switched to the active state. The director checks that all the DEU current-sensing bits are activated. There is no test available for the opto-coupled outputs.
1EFF : 001-049, 051-099, 101-105, 151-199, 1 23-73-00Page 69 1201-299, 1Config-1 Aug 01/05R 1 1 1CES 1
DEU Connection to Data Bus Power Supply and Address Coding
Figure 022
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 23-73-00Page 70 1201-299, 1Config-1 May 01/05 1 1 1CES 1
INTENTIONALLY BLANK
R 1 1
23-73-00Page 71
1 1 Config-1 May 01/05 1 1 1CES 1
DEU A - Connections to Cabin Systems Figure 023 (SHEET 1)
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 23-73-00Page 72 1201-299, 1Config-1 May 01/05 1 1 1CES 1
DEU A - Connections to Cabin Systems Figure 023 (SHEET 2)
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 23-73-00Page 73 1201-299, 1Config-1 May 01/05 1 1 1CES 1
DEU B - Connections to Cabin Systems Figure 024 (SHEET 1)
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 23-73-00Page 74 1201-299, 1Config-1 May 01/05 1 1 1CES 1
DEU B - Connections to Cabin Systems Figure 024 (SHEET 2)
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 23-73-00Page 75 1201-299, 1Config-1 May 01/05 1 1 1CES 1
2_ Discrete inputs
- The director checks that no discrete inputs are active. Some
input circuit failures cannot be detected by the director.
These failures are only apparent when the appropriate input
is activated. It is also possible that a fault in equipments
connected to the director to mistaken for a faulty input
circuit.
3_ PA amplifier volume control, frequency control and audio
output
- The director generates a test signal, and the DEU audio
outputs are monitored for correct action of the respective
circuits. These tests are only done if a loudspeaker is
connected.
4_ No smoking, fasten seat belt, return to seat and passenger
call lamps (not applicable for LED NS/FSB signs)
- All lamp-outputs are set to OFF. The director controls the
DEU's current-limit threshold for the lamp drivers. It also
commands the DEU to turn on one lamp at a time. In this way,
any open-circuit lamps are detected. This test also detects
a failed current-detector.
5_ The DEU A power supply, gate array, bus interface and BITE
status are also checked.
- The major DEU tests are continuously done for the whole time
that the CIDS is switched on. In normal operation the
director transmits information continuously to the DEUs.
When a DEU is addressed, it must respond with a parity
bit-coded message. If this response message is absent (or
the parity bit is wrong for a minimum of 4 transmissions),
then the DEU is declared to be unserviceable.
(c) DEU B Power-Up Tests These are tested at this stage
1 Discrete outputs, as for DEU A described in paragraph
_ 6.B.(2)(b)-1.
2 Discrete inputs, as for DEU A described in paragraph
_ 6.B.(2)(b)-2.
3 Audio Input/Output. The DEU B is commanded to perform a
_ loop-back operation, where the handset output is electronically connected to the handset input. The director transmits a test signal to the DEU B. After all the audio circuitry of the DEU B have processed this signal, it is
1EFF : 001-049, 051-099, 101-105, 151-199, 1 23-73-00Page 76 1201-299, 1Config-1 Aug 01/05R 1 1 1CES 1
transmitted back to the director. The director can analyse the
signal for frequency response and audio level. The test is
also automatically performed, when a handset is unhooked.
Signal-to-noise ratio, total distortion, and handset supply
are not tested.
4_ Serial Input/Output. Under control of the director, several
types of tests are performed to check for faulty operation:
- the register read/write test,
- the timing test,
- the status bit test,
- the parity bit test,
- the data loopback test (in conjuction with the connected
hardware).
The results of the loopback test assume the connected device
is operational.
5_ EVAC indicator lamp. As for discrete outputs described in
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM Communications 通讯3(53)