R R R R R R R R R R 121VU COM NAV/CIDS/DEU A NORM/R AFT 121VU COM NAV/CIDS/DEU A NORM/L AFT 121VU COM NAV/CIDS/DEU A NORM/R MID 121VU COM NAV/CIDS/DEU A NORM/L MID 121VU COM NAV/CIDS/DEU A NORM/R FWD 121VU COM NAV/CIDS/DEU A NORM/L FWD 121VU COM NAV/CIDS/DEU B/NORM 121VU COM NAV/CIDS/PROG &/TST PNL 121VU COM NAV/CIDS/DIR NORM/2 121VU COM /CIDS/FLT ATTND/PNL 168RH 167RH 166RH 165RH 164RH 163RH 162RH 161RH 156RH 170RH M14 M13 M12 M11 M10 M09 M08 M07 M06 Q14
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
122VU AIR COND/CAB PRESS/CTL/2 2HL Y22
4. Procedure_________
Subtask 23-73-00-869-069
A. PA level adjustment (Ref. Fig. 209/TASK 23-73-00-991-006)
(1) On the PTP 110RH push the DSPL ON pushbutton switch. - the CIDS menu page comes on.
(2) Push the <PROGRAMMING related membrane switch. - the PROGRAMMING menu page comes on.
(3) Push the <CABIN PROGRAMMING related membrane switch. - the ENTER ACCESS CODE page comes on.
(4) Enter the access code 333 123 to the scratchpad field and push the <ENTER related membrane switch. - the next page with the <PA LEVEL ADJ message comes on.
(5) Push the <PA LEVEL ADJ related membrane switch. - the PA LEVEL ADJ page comes on.
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 23-73-00Page 270 1201-299, 1May 01/05 1 1 1CES 1
PA Level Adjustment
Example
Figure 209/TASK 23-73-00-991-006
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 23-73-00Page 271 1201-299, 1May 01/05 1 1 1CES 1
(6) push the <CABIN IN DETAIL related membrane switch.
-the CABIN SEG page comes on.
NOTE : The cabin segments are not equivalent to the cabin zones. The
____ locations of the cabin segments are shown in the CFDS PA LEVEL REPORT (Ref. TASK 23-73-00-860-005).
(7)
Push the related SEG membrane switch to select the cabin segment.
-
the respective segment value flashes.
-
the <+ (DB) and <- (DB) prompts appear.
(8)
Push the + or - related membrane switches to change the PA level value.
NOTE : The values are adjustable in 2 dB steps. The respective PA
____ level in the cabin is updated immediately.
(9) Select the next cabin segment for updating or push the CONT> related membrane switch to get access to the ATTND page.
(10) After the update of all PA levels push the <RET related membrane switch to save the new PA levels.
NOTE : If a reset to the default PA level is necessary, select the
____ related cabin segment or attendant station and push the <RES related membrane switch. Pushing the <RES related membrane switch, without selection of a cabin segment or an attendant station, resets all to the default values.
(11) For an update of the auto increase of the PA level select the <AUTO INCREASE membrane switch on the PA LEVEL ADJ page. The procedure is the same as for the cabin segment and attendant station PA level adjustment.
5. Close-up
________
Subtask 23-73-00-869-070
A. Push the DSPL On pushbutton switch.
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 23-73-00Page 272 1201-299, 1May 01/05 1 1 1CES 1 **ON A/C ALL
TASK 23-73-00-860-005
Passenger Address (PA) Level Interrogation via CFDS
1.
Reason for the Job
__________________
Self Explanatory