Subtask 23-72-22-710-050 R E. Do the Operational Test of the Anti-Hijack Camera-System (Ref. TASK 23-72-00-710-001). **ON A/C 216-216,
5. Close-up
________
**ON A/C 216-216,
Post SB 23-1208 For A/C 216-216,
Subtask 23-72-22-410-050
A. Close Access
(1) Make sure that the work area is clean and clear of tool(s) and other items.
Subtask 23-72-22-862-050
B. De-energize the ground service network
(Ref. TASK 24-41-00-862-002)
1EFF : 216-216, 1 23-72-22Page 409 1 1 Nov 01/04 1 1 1CES 1 CAMERA - ANTI HIJACK SYSTEM - REMOVAL/INSTALLATION
__________________________________________________
TASK 23-72-51-000-001
Removal of the Anti-Hijack-System Cameras
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific blanking caps
No specific circuit breaker(s) safety clip(s)
B. Referenced Information -------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External
Power R 25-23-42-000-001 Removal of the Ceiling Panels - Forward Utility Area **ON A/C 216-216, Post SB 23-1208 For A/C 216-216, 23-72-51-991-001 Fig. 401
1EFF : 216-216, 1 23-72-51Page 401 1 1 Feb 01/04 1 1 1CES 1 **ON A/C 216-216,
3. Job Set-up
__________ **ON A/C 216-216, Post SB 23-1208 For A/C 216-216, Subtask 23-72-51-861-050
A. Energize the ground service network
(Ref. TASK 24-42-00-861-001).
Subtask 23-72-51-865-050
B. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
122VU DOORS/CKPT/VIDEO/SPLY 15RA T16
**ON A/C 216-216,
4. Procedure
_________ **ON A/C 216-216, Post SB 23-1208 For A/C 216-216, Subtask 23-72-51-020-050
A. Removal of the Cameras
(Ref. Fig. 401/TASK 23-72-51-991-001)
NOTE : The removal procedure for all the cameras is the same. Only one
____
procedure is given.
(1)
Remove the caps (4).
(2)
Hold the camera (3) in position.
(3)
Remove the screws (5) and the washers (6).
1EFF : 216-216, 1 23-72-51Page 402 1 1 May 01/03 1 1 1CES 1
Cameras
Figure 401/TASK 23-72-51-991-001
1EFF : 216-216, 1 23-72-51 Page 403
1 1 May 01/03
1 1
1CES 1
(4) Carefully remove the camera (3) until you can disconnect the
electrical connector (1).
(5) Disconnect the electrical connector (1) and remove the camera (3).
R (6) If you cannot get access to disconnect the electrical connector (1),
R do the subsequent steps:
R (a) Loosely attach the camera (3) to the ceiling panel with the
R screws (5).
R (b) Remove the ceiling panel and move it until you can get access to
R the electrical connector (1) (Ref. TASK 25-23-42-000-001).
R (c) Disconnect the electrical connector (1) from the camera (3).
R (d) Remove the three screws (5) and remove the camera (3) from the
R ceiling panel.
R (7) Put blanking caps on the disconnected electrical connectors.
1EFF : 216-216, 1 23-72-51Page 404 1 1 Feb 01/04 1 1 1CES 1 **ON A/C 216-216,
TASK 23-72-51-400-001
Installation of the Anti-Hijack-System Cameras
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
11-00-00-400-007 Installation of the ESSO (Scotchcal Labels)
23-72-00-710-001 Operational Test of the Anti-Hijack