4. Procedure
_________ R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
Subtask 23-73-00-869-065
A. Programming of cabin zones
(Ref. Fig. 202/TASK 23-73-00-991-002)
(1)
On the PTP 110RH push the DSPL ON membrane switch.
-the CIDS menu page comes on.
(2)
Push the <PROGRAMMING related membrane switch.
-the PROGRAMMING menu page comes on.
(3)
Push the <ZONING related membrane switch.
-the ZONING menu page comes on.
(4)
Push the <CABIN ZONES related membrane switch.
-the CABIN ZONES menu page comes on.
(5)
Enter the number of the seatrow number to the scratchpad field.
(6)
Push the related membrane switch to push the scratchpad field to the selected data field.
(7)
Push the <RET related membrane switch to save the new config to layout M.
(8)
The message PARAMETER SAVING flashes a few seconds and the menu PARAMETER SAVED with the modification number comes on.
(9) Push the <RET related membrane switch.
Subtask 23-73-00-869-066
B. Programming of No Smoking Zones
(Ref. Fig. 203/TASK 23-73-00-991-003)
(1) On the PTP 110RH push the DSPL ON membrane switch.
-the CIDS menu page comes on.
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 23-73-00Page 229 1201-299, 301-399, 1May 01/05 1 1 1CES 1
Cabin Zones Programming
Example
Figure 202/TASK 23-73-00-991-002
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 23-73-00Page 230 1201-299, 1May 01/05 1 1 1CES 1
No Smoking Zones Programming
Example
Figure 203/TASK 23-73-00-991-003
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 23-73-00Page 231 1201-299, 1May 01/05 1 1 1CES 1
(2)
Push the <PROGRAMMING related membrane switch.
-the PROGRAMMING menu page comes on.
(3)
Push the <ZONING related membrane switch.
-the ZONING menu page comes on.
(4)
Push the <NS ZONES related membrane switch.
-the NS END ZONES menu page comes on.
NOTE : If a NON SMOKER A/C is programmed, the NS SIGNS / NON SMOKER
____ A/C SELECTED page comes on. To program a smoker area push the NORMAL> related membrane switch.
(5)
Enter the number of the seatrow number to the scratchpad field.
(6)
Push the related membrane switch to push the scratchpad field to the selected data field.
(7)
Push the <RET related membrane switch to save the new config to layout M.
(8)
The message PARAMETER SAVING flashes a few seconds and the menu PARAMETER SAVED with the modification number comes on.
(9) Push the <RET related membrane switch. R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-210,
Subtask 23-73-00-869-067
C. Activation - Deactivation of the Active Class Divider
(Ref. Fig. 204/TASK 23-73-00-991-004)
(1)
On the PTP 110RH push the DSPL ON membrane switch.
-the CIDS menu page comes on.
(2)
Push the <PROGRAMMING related membrane switch.
-the PROGRAMMING menu page comes on.
(3)
Push the <ZONING related membrane switch.
-the ZONING menu page comes on.
(4)
Push the DIV> related membrane switch.
-the CLASS DIVIDER menu page comes on.
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 23-73-00Page 232 1201-299, 1May 01/05 1 1 1CES 1
Class Divider Activation - Deactivation
Example
Figure 204/TASK 23-73-00-991-004
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 23-73-00Page 233 1201-299, 1May 01/05 1 1 1CES 1
(5)
Push for change the related membrane switch. NOTE : Pushing the membrane switch changes the active class divider
____ to passive and the passive to the active condition.
(6)
Push the <RET related membrane switch.
(7)
The message PARAMETER SAVING flashes a few seconds and the menu PARAMETER SAVED with the modification number comes on.
(8) Push the <RET related membrane switch. R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-399,
5. Close-up
________ R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
Subtask 23-73-00-869-068
A. Push the DSPL On pushbutton switch.
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 23-73-00Page 234 1201-299, 301-399, 1May 01/05 1 1 1CES 1