• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-20 21:14来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (zonewise) fail or
 - more than 50 % of all NS-FSB Signs and PA inoperative (resp.
 DEU A) fail (the CIDS CAUTION light also comes on),
 - all DEU B with connected handset fail (the CIDS CAUTION
 light also comes on).
 2_ 'CIDS CAUTION' on ECAM
 The directors output 'CIDS CAUTION' to the SDAC is at active
 ground when there are no failures in the CIDS. A change in
 this state results in 'CIDS CAUTION' 'CIDS 1' or 'CIDS 2' at
 the ECAM when:
 - one director there is fail,
 - there is no data from the other director via crosslink.
 The director continues to signal CIDS CAUTION to the SDAC
 until the fault is corrected.
 The director continues to signal CIDS CAUTION to the SDAC
 until the fault is corrected.
 3_ CIDS CAUTION light activated at the FWD ATTND panel (FAP)
 The director sends a signal to the FWD ATTND panel via the
 ARINC link to activate the CIDS CAUTION light when:
 - one director fails,
 - two directors fail,
 - all DEU B with connected handsets fail,

 1EFF : 001-049, 051-099, 101-105, 151-199, 1 23-73-00Page 55 1201-299, 1Config-1 Aug 01/05R 1 1 1CES 1


 -more than 50% of all DEU A or 20% of adjacent DEU A zonewise fail,
 -no data from SDCU channel 1 and 2,
 -
the drainmast system fails,

 -
the emergency slide bottle pressure is low,

 -
the slide bottle pressure is low,

 -
the door bottle pressure is low,

 -
the lavatory smoke detection fails,
 - one DEU A fails,
 - one DEU B fails,


 -
the CIDS top bus fails,


 -
the CIDS mid bus fails,


 -
the FAP fails,


 -
the PTP fails,


 -
the CAM fails,

 

 -
no data from FAP,


 -
no data from CAM,


 -
no data from PTP.
 The CIDS CAUTION light is resettable in flight, but comes on
 again on the ground (landing gear down and locked). The light
 cannot be reset on the ground. When a CIDS CAUTION occurs, the
 respective failure message is displayed on the programming and
 test panel. The director will perform, or cause a CIDS
 component test to be done, when commanded from the programming
 and test panel. This is described under 'System Testing and
 Programming'.
 The function of the director with respect to these systems is
 described in the 'System Operation' section:

 

 -
the PA system,


 -
the interphone system,


 -
the lighted signs,


 -
the PAX call.
 For other systems, refer to the appropriate system chapters.
 There remains, however, other aspects to the director's
 operation, and these are described in the text shown below.
 (Ref. Fig. 010).

 

 (c) Emergency Mode Activation For reduction of power consumption, the director has the capability to activate an emergency mode. The emergency mode causes all sections of the director which are not permanently in use to switch off. The sections of the director and the cabin systems control circuits which are not switched off are:
 -
the power supply,

 -
the microcomputer,

 -
the CIDS data bus driver,

 -
the PA system,


 1EFF : 001-049, 051-099, 101-105, 151-199, 1 23-73-00Page 56 1201-299, 1Config-1 Aug 01/05R 1 1 1CES 1


 -
the interphone,

 -
the EVAC. The power supply for top lines is also disconnected. This is done when no power is detected at the 'normal power sensing' input and no PA announcement is made. The director then applies a 28 V DC output to the 'Top Line Cut-off Relay 106RH' output.


 **ON A/C 001-049, 051-099, 101-105, 201-299,
 (d) Power Sensing As long as power is available at power input one, it supplies the director. In the event of a power failure at this input, the director automatically switches over to supply input two. If power is detected at the 'Normal Power Sensing' input (and the director is operative), then the output 'Power Transfer Relay' is switched to active ground. The connected relay 105RH is held in the energized state. Failure in the output deenergizes the relay. This connects essential power and transfers control of the top-line cut-off relay 106RH to the other director.
 **ON A/C 151-199,
 (d) Power Sensing As long as power is available at power input one (NORM), it supplies the director. In the event of a power failure at this input, the director automatically switches over to supply input two (ESS).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM Communications 通讯3(49)