R FAP - Cabin Lighting Page (only Cabin Lighting related buttons labeled) -
R Example
R Figure 042B
R 1EFF : 401-499, 1 23-73-00 Page A26
1 1 Config-2 Aug 01/05
1 1
1CES 1
R **ON A/C 106-149, 401-499,
In the following areas a fine adjustment of the light intensity is possible: - Pax areas.
R **ON A/C 106-149, 301-399, 401-499,
Additionally the light control is available on the AAP.
(d) Signal transmission The settings initiated on the FAP are sent directly to the CIDS director, whereas the AAP settings are sent via the respective DEU type B to the CIDS director. The director sends commands via the top lines to the DEUs type A. The DEUs type A control with help of these commands the light intensitiy of the general illumination ballast units.
(e) Automatic activation With one or more engines running (oil pressure high), the light intensity is dimmed automatically in the FWD entrance area if the cockpit door is open. In case of low cabin-pressure all lights are switched on with full brightness independently from all other light volume settings.
(10) Reading Lights
**ON A/C 301-399,
(Ref. Fig. 043)
R **ON A/C 106-149, 301-399, 401-499,
(a) General The reading light system controls the passenger reading lights and attendant work lights in the cabin. (Ref. 33-25-00)
R R R (b) Operation The reading lights are controlled by the pushbuttons on the overhead Passenger Service Unit (PSU). The attendant work lights are controlled by pushbuttons in the attendant area.
R 1EFF : 106-149, 301-399, 401-499, 1 23-73-00Page A27 1 1 Config-2 Aug 01/05 1 1 1CES 1
Reading Lights - Block Diagram
Figure 043
1EFF : 301-399, 1 23-73-00Page A28 1 1 Config-2 Aug 01/05R 1 1 1CES 1
(c)
Signal transmission If the reading lights are switched on/off from the PSUs, a signal is sent directly to the PISA or reading light. If the attendant work lights are switched on/off from the attendant work stations, a signal is sent directly to the StA PISA. When the signal is sent to the reading light, the reading light is switched on/off directly. When the PISAs or StA PISAs receive the signal, they switch on/off the reading lights and attendant work lights.
(d)
Reset function
**ON A/C 106-149,
(Ref. Fig. 044)
**ON A/C 301-399,
(Ref. Fig. 044A)
R **ON A/C 401-499,
R (Ref. Fig. 044B)
R **ON A/C 106-149, 301-399, 401-499,
It is possible to reset all reading lights from a pushbutton on the FAP. This function is only available with the landing gear down and compressed (LGCIU).
(e) All reading lights on It is possible to switch on all reading lights via FAP. This function is only available with the landing gear down and compressed (LGCIU).
(11) Lavatory smoke detection
**ON A/C 106-149,
(Ref. Fig. 045)
R 1EFF : 106-149, 301-399, 401-499, 1 23-73-00Page A29 1 1 Config-2 Aug 01/05 1 1 1CES 1
FAP - Cabin Lighting Page (only Reading Lights related buttons labeled) -
Example
Figure 044
R 1EFF : 106-149, 1 23-73-00 Page A30
1 1 Config-2 Aug 01/05
1 1
1CES 1
FAP - Cabin Lighting Page (only Reading Lights related buttons labeled) -
Example
Figure 044A
R 1EFF : 301-399, 1 23-73-00 Page A31
1 1 Config-2 Aug 01/05
1 1
1CES 1
R FAP - Cabin Lighting Page (only Reading Lights related buttons labeled) -
R Example
R Figure 044B
R 1EFF : 401-499, 1 23-73-00 Page A32
1 1 Config-2 Aug 01/05
1 1
1CES 1
Lavatory Smoke Detection - Block Diagram
Figure 045
R 1EFF : 106-149, 1 23-73-00Page A33 1 1 Config-2 Aug 01/05 1 1 1CES 1 **ON A/C 301-399,
(Ref. Fig. 045A)
**ON A/C 106-149,
(Ref. Fig. 046)
**ON A/C 301-399,
(Ref. Fig. 046A)
R **ON A/C 106-149, 301-399, 401-499,
(a)
General The lavatory smoke detection function is part of the CIDS Smoke Detection Function (CIDS-SDF). The CIDS does the visual and acoustical indications in the cabin, if a lavatory smoke alert is detected by the CIDS-SDF. (Ref. 26-17-00)