R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 23-73-00Page 506 1201-299, 1May 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
4. On the C/B panel 121VU:
-after approx. 10 s close the
C/B DIR 1 AND 2/NORM 151RH.
5. On the C/B panel 49VU:
-close the C/B DIR 1 AND 2/ESS - the CIDS CAUT light goes off.
150RH.
NOTE : Wait approx. 5 min before you start the next test step.
____
6. On the Programming and Test Panel (PTP) 110RH:
-
push the DSPL ON membrane
switch.
-
push the SYSTEM STATUS related membrane switch.
-
push the CONT related membrane switch until the < MAINTENANCE message comes on.
-
push the MAINTENANCE related membrane switch.
-
push the CONT related membrane switch until the < GND SCAN message comes on.
-
push the GND SCAN related
membrane switch.
-
push the RET related membrane switch until the SYSTEM STATUS page comes on.
-after approx. 5 min the CIDS CAUT light is still off.
In the cockpit on the UPPER and LOWER ECAM DISPLAY:
-all CIDS FAULT messages are off.
On the PTP 110RH:
-
the CIDS menu page comes on.
-
the SYSTEM STATUS page comes on withsystem OK messages.
-
the next system status related pageswith system OK messages come on.
-
the MAINTENANCE page comes on.
-
the GND SCAN page with the NO FAILUREmessage comes on.
-
the SYSTEM STATUS page comes on.
R 1EFF : 001-049, 051-099, 101-105, 201-299, 1 23-73-00Page 507 1 1 May 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
- push the CONT related membrane
switch until the < MAINTENANCE
message comes on.
- push the MAINTENANCE related - the MAINTENANCE page comes on.
membrane switch.
- push the CONT related membrane - the < CLASS 3 FAULTS message comes
switch. on.
- push the < CLASS 3 FAULTS - the CLASS 3 FAULT page with NO
related membrane switch. FAILURE messages comes on.
NOTE : An erroneous CLASS 3 FAULT message will be recorded for each LED
____ (without bulbs) Cabin Sign; if the test of the related signs is not deactivated in the CAM.
-push the DSPL ON membrane - the CIDS menu page comes on.
switch.
**ON A/C 151-199,
Subtask 23-73-00-740-051-A
A. Do this test.
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1.
On the C/B panel 49VU:
- open the C/Bs DIR ESS/1 and DIR ESS/2 150RH and 157RH.
2.
On the C/B panel 121VU:
- open the C/Bs DIR NORM/1 and DIR NORM/2 151RH and 156RH.
On the Forward Attendant Panel (FAP) 120RH:
-the CIDS CAUT light comes on. On the PTP 110RH:
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 23-73-00Page 508 1201-299, 1May 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
3. On the ECAM Control-Panel (ECP):
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM Communications 通讯3(137)