R 1EFF : 106-149, 301-399, 401-499, 1 23-73-00Page 243 1 1 Aug 01/05 1 1 1CES 1 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------**ON A/C 301-399,
121VU COM NAV/CIDS/DEU A NORM/R FWD 164RH M11 121VU COM NAV/CIDS/DEU A NORM/L FWD 163RH M10 121VU COM NAV/CIDS/DIR NORM/2 156RH M07 121VU COM NAV/CIDS/DIR NORM/1 151RH M06 121VU COM NAV/CIDS/FWD ATTND/PNL 170RH Q14
R **ON A/C 106-149, 301-399, 401-499,
122VU AIR COND/CIDS/SDF/DIR NORM/2 14WH T18 122VU AIR COND/CIDS/SDF/DIR NORM/1 17WH T17 122VU AIR COND/CAB PRESS/CTL/2 2HL Y22
**ON A/C 301-399,
Subtask 23-73-00-865-209
C. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
-------------------------------------------------------------------------------
2001VU CIDS/DEU A NORM/ MID/ LH 197RH C04
2001VU CIDS/DEU A NORM/ MID/ RH 198RH C05
2001VU CIDS/DEU A NORM/ AFT/ LH 173RH C06
2001VU CIDS/DEU A NORM/ AFT/ RH 174RH C07
2001VU CIDS/DEU B NORM/ AFT 194RH C08
R 1EFF : 106-149, 301-399, 401-499, 1 23-73-00Page 244 1 1 Aug 01/05 1 1 1CES 1R **ON A/C 106-149, 301-399, 401-499,
4. Procedure
_________
Subtask 23-73-00-869-076
A. Programming of Cabin Zones R **ON A/C 106-149, 401-499,
(Ref. Fig. 206/TASK 23-73-00-991-011)
**ON A/C 301-399,
(Ref. Fig. 206A/TASK 23-73-00-991-011-A) R **ON A/C 106-149, 301-399, 401-499,
(1)
On the FAP push the CABIN PROG key.
-
the CABIN PROG key is illuminated.
-
the CABIN PROGRAMMING page with an activated ENTER ACCESS CODE window comes on.
(2)
On the numeric keyboard of the ENTER ACCESS CODE window enter the access code 318 and push the ENTER key.
-the ENTER ACCESS CODE window disappears.
(3)
On the CABIN PROGRAMMING page push the related CABIN ZONES key.
-
the CABIN ZONES key is illuminated.
-
the related CABIN ZONES window comes on.
NOTE : It is possible to select in addition to the zone programming
____ the non smoker area programming, if a NON SMOKER A/C is not selected. (Refer to the Non Smoker Area programming)
(4) On the CABIN ZONES window push the related 'Up' or 'Down' key to change the end of the cabin zone.
-the selected seatrow numbers are indicated online.
NOTE : A minimum of one seatrow must remain in each cabin zone. A
____
cabin zone can not be deleted.
R 1EFF : 106-149, 301-399, 401-499, 1 23-73-00Page 245 1 1 Aug 01/05 1 1 1CES 1
Cabin Zones Programming - Example
Figure 206/TASK 23-73-00-991-011- 13 (SHEET 1)
R 1EFF : 106-149, 401-499, 1 23-73-00Page 246 1 1 Aug 01/05 1 1 1CES 1
Cabin Zones Programming - Example
Figure 206/TASK 23-73-00-991-011- 23 (SHEET 2)
R 1EFF : 106-149, 401-499, 1 23-73-00Page 247 1 1 Aug 01/05 1 1 1CES 1
Cabin Zones Programming - Example
Figure 206/TASK 23-73-00-991-011- 33 (SHEET 3)
R 1EFF : 106-149, 401-499, 1 23-73-00Page 248 1 1 Aug 01/05 1 1 1CES 1
INTENTIONALLY BLANK
R 1 1
23-73-00Page 249
1 1 May 01/05 1 1 1CES 1
Cabin Zones Programming - Example R Figure 206A/TASK 23-73-00-991-011-A13 (SHEET 1)
1EFF : 301-399, 1 23-73-00Page 250 1 1 May 01/05 1 1 1CES 1
Cabin Zones Programming - Example R Figure 206A/TASK 23-73-00-991-011-A23 (SHEET 2)
1EFF : 301-399, 1 23-73-00Page 251 1 1 May 01/05 1 1 1CES 1
Cabin Zones Programming - Example R Figure 206A/TASK 23-73-00-991-011-A33 (SHEET 3)
1EFF : 301-399, 1 23-73-00Page 252 1 1 May 01/05 1 1 1CES 1
(5) On the CABIN PROGRAMMING page push the activated CABIN ZONES key.