 illumination in all entrance areas and the integral light.
 4_ ENTRY DIM 1
 The ENTRY DIM 1 membrane switch, switches on the general
 illumination in all entrance areas with a brightness of
 approx. 50%. The integral light in the membrane switch comes
 on. Pushing the membrane switch a second time, switches off
 the general illumination in all entrance areas and the
 integral light.
 5_ ENTRY DIM 2
 The ENTRY DIM 2 membrane switch, switches on the general
 illumination in all entrance areas with a brightness of
 approx. 10%. The integral light in the membrane switch comes
 on. Pushing the membrane switch a second time, switches off
 the general illumination in all entrance areas and the
 integral light.

 **ON A/C 051-099, 151-199, 211-299,
 3 ENTRY FWD BRT/ENTRY AFT BRT
_ The ENTRY FWD BRT or ENTRY AFT BRT membrane switches, switch on the general illumination in the respective entrance area with a brightness of 100%. The integral light in the membrane switch comes on. Pushing the membrane switch a second time, switches off the general illumination of the respective entrance areas and the integral lights.
 4 ENTRY FWD DIM 1/ENTRY AFT DIM 1
_ The ENTRY FWD DIM 1 or ENTRY AFT DIM 1 membrane switches, switch on the general illumination in the respective entrance areas with a brightness of approx 50%. The integral lights in the membrane switches come on. Pushing the membrane switches a second time, switches off the general illumination in the respective areas and the integral lights.
 1EFF : 001-049, 051-099, 101-105, 151-199, 1 23-73-00Page 88 1201-299, 1Config-1 Aug 01/05R 1 1 1CES 1


 5_ ENTRY FWD DIM 2/ENTRY AFT DIM 2
 The ENTRY FWD DIM 2 or ENTRY AFT DIM 2 membrane switches,
 switch on the general illumination in the respective entrance
 areas with a brightness of approx. 10%. The integral lights in
 the membrane switches come on. Pushing the membrane switches a
 second time, switches off the general illumination in the
 respective entrance areas and the integral lights.

 **ON A/C 001-049, 051-099, 101-105,
 6 CABIN LIGHTING/BRT/DIM 1/DIM 2
_ The CABIN LIGHTING/BRT/DIM 1/DIM 2 membrane switches, for the cabin, have the same function as the ENTRY/BRT/DIM 1/DIM 2 membrane switches, for the entrance area.
 **ON A/C 151-199,
 6 CABIN LIGHTING/BRT/DIM 1/DIM 2
_ The CABIN LIGHTING/BRT/DIM 1/DIM 2 membrane switches, for the cabin, have the same function as the ENTRY/BRT/DIM 1/DIM 2 membrane switches, for the entrance area.
 **ON A/C 201-299,
 6 CABIN LIGHTING/BC/YC/BRT/DIM 1/DIM 2
_ The CABIN LIGHTING/BC/YC/BRT/DIM 1/DIM 2 membrane switches, for the cabin area, have the same function as the ENTRY/BRT/DIM 1/DIM 2 membrane switches, for the entrance area.
 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
 7 CABIN LIGHTING WDO
_ When the general illumination for a cabin area is switched on, the CABIN LIGHTING WDO membrane switch integral light comes on. Pushing the membrane switch, switches off the general illumination at the windows left and right and the integral light. Pushing the membrane switch a second time, switches on the general illumination at the windows and the membrane switch integral light comes on.
 1EFF : 001-049, 051-099, 101-105, 151-199, 1 23-73-00Page 89 1201-299, 1Config-1 Aug 01/05R 1 1 1CES 1


 8_ CABIN LIGHTING CLG
 When the general illumination for a cabin area is switched on,
 the CABIN LIGHTING CLG membrane switch integral light goes on.
 Pushing the membrane switch, switches off the general
 illumination in the ceiling and the integral light. Pushing
 the membrane switch a second time switches on the general
 illumination in the ceiling and the membrane switch integral
 light comes on.
 9_ POWER READ
 The POWER READ membrane switch, switches on the power supply
 for the reading lights. The integral light in the membrane
 switch comes on. Pushing the membrane switch a second time
 switches off the power supply and the membrane switch integral
 light goes off.
 10__ POWER ATTN
 The POWER ATTN membrane switch, switches on the power supply
 for the attendant work lights. The integral light in the
 membrane switch comes on. Pushing the membrane switch a second
 time switches off the power supply and the membrane switch
 integral light goes off.
 11__ POWER LAV
 The POWER LAV membrane switch, switches on the power supply
 for the lavatory lights to a brightness of approx. 50%. The
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn