On the display of the Data Loading Selector:
-DB/N: PUSH NEXT/PREV indication is shown.
On the multipurpose disk drive unit:
-the < < MDDU READY > > indication is shown.
On the display of the Data Loading Selector:
-FMGC1(2) NOT SELECTED indication is shown,
-FMGC1(2) SELECTED indication is shown.
On the multipurpose disk drive unit:
-the READY indication is shown,
-then, the WAIT RESPONSE indication is shown.
On the multipurpose disk drive unit:
-the BUS n: xxxxxxx indication is shown after the FMGC safety test,
-When all the data are put into the computer (a time duration of 25 minutes can be necessary), the TRANS IN PROG then TRANSF COMPLETE indication is shown.
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R NOTE : The n indication is the number____
R of the bus in transfer comprised
R between 1 to 8.
R The xxxxxxx indication is the
R number of remaining bytes to be
R transfered.
R
R NOTE : If DISK ERROR is shown at the____
R beginning of the loading, eject
R and put again the disk into the
R MDDU. Do not do steps 4, 5 and 6
R again.
R If READY and WAIT RESPONSE
R indications are shown at the end
R of the loading, eject the disk.
R Do step 7 and do not do step 8.
R 7. On the overhead panel, on the On the display of the Data Loading
R Data Loading Selector: Selector:
R - push the SEL CTL key. - FMGC1(2)
R NOT SELECTED
R indication is shown.
R 8. Eject the disk from the disk On the multipurpose disk drive unit:
R drive. - the < < MDDU READY > > indication is
R shown.
R 9. On the Data Loading Selector:
R - set the ON/OFF switch to OFF.
R 10. Open the circuit breaker
R 10CA1(2) for more than 5
R seconds.
R 11. Close the circuit breaker 10CA1
R and 10CA2, and wait for FMGC
R safety test.
**ON A/C 151-199, 201-212,
Subtask 22-70-00-280-069
B. Check of the Active Data Base of the loaded FMGC (use the corresponding MCDU).
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the MCDU1(2):
-push the MCDU MENU mode key. The MCDU MENU page comes into view
2.
Push the line key adjacent to the The FM page comes into view FMGC indication.
3.
Push the DATA mode key. The DATA INDEX page comes into view.
4.
Push the line key adjacent to the The A/C status page comes into view. A/C STATUS indication.
5.
Make sure that the ACTIVE DATA BASE is correct for dates shown and that the reference is the same as the DB/N reference read on the disk for the loaded FMGC.
R **ON A/C 106-149, 151-199, 211-299, 301-399, 401-499, Post SB 22-1089 For A/C 151-199,211-212, Subtask 22-70-00-280-069-A
B. Do a check of the reference of the software loaded in the FMGC, on the MCDU:
(1) Make sure that the P/N XLOAD 1/6 page is shown on the MCDU:
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the MCDU: On the MCDU:
-Get the page related to the - Make sure that the reference (P/N) loaded element (use the line shown is the same as the reference on select key adjacent to the NEXT the disk(s). PAGE or PREV PAGE indication).