ACTION RESULT -------------------------------------------------------------------------------
11. Close the circuit breaker 10CA1
and 10CA2, and wait for FMGC
safety test.
R **ON A/C 106-149, 151-199, 211-299, 301-399, 401-499,
Post SB 22-1089 For A/C 151-199,211-212,
Subtask 22-70-00-970-068-B
A. Uploading of the FMGC
NOTE : When the uploading of the FMGC is completed, you can use the XLOAD
____ function to load the other FMGC (Ref. TASK 22-70-00-610-009).
NOTE : The uploading time for one full disk is twelve minutes
____
approximately.
NOTE : After the uploading operations, you must do a check of the
____ reference of the data loaded in the FMGC, on the MCDU.
NOTE : The uploading procedure that follows is for the FMGC1. For the
____ FMGC2 procedure which is the same, refer to the data in parentheses.
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the overhead panel, on the On the display of the Data Loading
Data Loading Selector: Selector:
-Set the ON/OFF switch to ON. - DB/N
PUSH NEXT/PREV
indication is shown.
On the MDDU:
-The < < MDDU READY > > indication is shown.
2. On the overhead panel:
-Open the circuit breakers 10CA1
and 10CA2.
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
3. On the Data Loading Selector: On the display of the Data Loading Selector:
- Push the PREV or NEXT key until you get the indication of the FMGC that you can load - FMGC1(2)NOT SELECTEDindication is shown
- Push the SEL CTL key. - FMGC1(2) SELECTED
indication is shown.
4. Use the applicable disk(s) from the disk storage box.
5. On the MDDU: On the MDDU:
- Put the disk into the disk - The READY indication comes into view
drive. - Then, the WAIT RESPONSE indication comes into view.
6. On the overhead panel: - Close the circuit breaker 10CA1 On the MDDU:- The READY indication comes into view
(10CA2). - Then, the WAIT RESPONSE indication comes into view and, immediately after, the TRANSF IN PROG indication comes into view
- the BUS n :xxxxxxx indication is
shown after the FMGC safety test.
NOTE : "n" is the number of the bus (1____ to 8) in transfer. "xxxxxx" is the number of
remaining bytes. The uploading is completed only when TRANSF COMPLETE indication
is shown.
NOTE : If more than one disk is____ necessary for the uploading, the EJECT DISK and INSERT NEXT DISK
indications show one after the
other. They tell the operator to put a new disk into the MDDU.
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
7. On the MDDU:
-Eject the disk from the disk drive.
8. On the overhead panel, on the Data Loading Selector:
-Push the SEL CTL key.
9.
Open (for more than 5 seconds) the circuit breaker 10CA1 (10CA2).
10.
On the Data Loading Selector:
-Set the ON/OFF switch to OFF.
11. Close the circuit breakers 10CA1 and 10CA2, and wait for FMGC safety test.
**ON A/C 151-199, 201-212,
Post SB 31-1130 For A/C 201-203,
Subtask 22-70-00-970-068-A
A. Uploading of the FMGC
-When all the disks are loaded in the FMGC, the TRANSF COMPLETE indication comes into view.
On the MDDU:
-The < < MDDU READY > > indicationcomes into view.
On the display of the Data LoadingSelector:
-FMGC1(2) NOT SELECTED indication is shown.
NOTE : This procedure is for FMGC1. For the FMGC2, which is identical,
____ use the indications between the parentheses.
NOTE : After the loading of one of the FMGCs, you can use the CROSSLOAD
____ function (Ref. TASK 22-70-00-610-009) to directly put the data into the other FMGC.