 A. This procedure contains these tasks:
 (1)  
The removal of the forward lavatory.

 (2)  
The installation of the forward lavatory.


 TASK 25-41-01-004-001
 2.  Remove Forward Lavatory (Fig. 401)_______________________
 A. General
 (1)  The forward galley, located directely across from the forward lava-tory will have to be disassembled to make clearance for the removal of the forward lavatory.
 B. References
 (1)  
AMM 25-41-02/401, Lavatory Door

 (2)  
AMM 38-10-00/201, Potable Water System

 (3)  
AMM 38-32-01/401, Toilet Tank

 (4)  
AMM 52-11-02/401, Passenger Door Lining


 C. Access
 (1)  Location Zones
 (a)  221 Passenger Cabin - Section 41 (Left)
 D. Prepare for Removal
 S 864-003
 (1)  Open this circuit breaker on the overhead circuit breaker panel, P11, and attach DO-NOT-CLOSE tag:
 (a)  11S8, LAV FLUSH MOTOR A
 S 864-004
 (2)  Open these circuit breakers on the APU external power panel, P34, and attach DO-NOT-CLOSE tags:
 (a)  
34B6, LIGHT LAV SERVICE

 (b)  
34D1, LAV LIGHTS OCCUPY DOME


 S 864-005
 (3)  Open this circuit breaker on the right miscellaneous electrical equipment panel, P37, and attach DO-NOT-CLOSE tag:
 (a)  37G3, LIGHTS LAV
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 25-41-01
 ALL  ú ú 01 Page 401 ú Jan 28/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

757
MAINTENANCE MANUAL

GASPER
PERMACELAIR HOSE
TAPE
0VERHEAD TIE
WATER SUPPLY LINE
STANCHION
PULLEY
COVER

ELECTRICAL AFT
CONNECTOR WALL
WATER TOILET
DRAIN LINES SHROUD
SEE A
TOILET
TANK
SEE B

B
A FLOOR MOUNT AND SHIM
A
(TYPICAL) B
SEE C
KICK STRIP AISLE WALL
STANCHION
LAVATORY
TRIM STRIP
SEALANT
AISLE WALL
TRIM
STRIP FLOOR PANEL
A-A  B-B
Forward Lavatory Installation
Figure 401 (Sheet 1)

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 25-41-01
 ALL  ú ú 01 Page 402 ú Jun 20/95
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL

CLOSED) DRAIN VALVE (NORMALLY  HOSE CLAMP  TOILET TANK 
C  C 
A  MOUNT FLOOR  DRAIN ADAPTER  B CLAMP  DRAIN LINE 
BOTTOM OF FLOOR MOUNT AND SHIM TOP OF BUSHING IN FLOOR SHIM 0.01 INCH MAX 
WASTE DRAIN ADAPTER  C  FLIGHT COMPARTMENT PARTITION 
LAVATORY FLOOR  (8 PLACES) SCREW 
SCREW  FWD 
C-C  FORWARD WALL ATTACHMENT  INBD 
Forward Lavatory Installation Figure 401 (Sheet 2) 

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 25-41-01
 ALL  ú ú 01 Page 403 ú Jun 20/95
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757 MAINTENANCE MANUAL
 S 864-007
 (4)  Open this circuit breaker on the miscellaneous electrical equipment panel, P70, and attach DO-NOT-CLOSE tag:
 (a)  70A1, LAV WTR HTR A
 S 024-110
 (5)  
Remove the doorway lining which is forward of the left No. 1 passenger door (AMM 52-11-02/401).

 S 014-013

 (6)  
Remove the ceiling panels to get access to the lavatory.

 S 864-067

 (7)  
Open the fill/overflow valve on the potable water service panel to decrease the pressure of the water system (AMM 38-10-00/201).

 S 014-015

 (8)  
Open the drain valve under the sink to drain the water lines and heater.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 EQUIPMENT/FURNISHINGS 2(7)