R  **ON A/C 401-499, 
R R  29-00-00-991-009-A Fig. 609A **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
R  29-00-00-991-010 **ON A/C 401-499,  Fig. 610 
R R  29-00-00-991-010-A Fig. 610A **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
R  29-00-00-991-011 **ON A/C 401-499,  Fig. 611 
R R  29-00-00-991-011-A Fig. 611A **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
R  29-00-00-991-012 **ON A/C 401-499,  Fig. 612 
R R  29-00-00-991-012-A **ON A/C ALL Fig. 612A 
3. Job Set-up__________ Subtask 29-00-00-010-053 A. Open the access doors 196BB, 198CB

 

 Subtask 29-00-00-865-052
 B. Make sure that this(these) circuit breaker(s) is(are) closed: -------------------------------------------------------------------------------
PANEL ------ DESIGNATION ------------------------------------------------------ IDENT. LOCATION-------------------
49VU FLIGHT CONTROLS/ELAC1/NORM/SPLY  15CE1  B11
 49VU FLIGHT CONTROLS/SEC1/NORM/SPLY  21CE1  B08
 105VU FLIGHT CONTROLS/ELAC2/STBY SPLY  16CE2  A02
 105VU FLT CTL/ELAC1/STBY SPLY  16CE1  A01
 105VU FLT CTL/SEC1/STBY SPLY  22CE  B01
 121VU AUTO FLT/FAC2/28VDC  5CC2  M19
 121VU AUTO FLT/FAC2/26VAC  14CC2  M18
 121VU HYDRAULIC/SOL VALVES/G/Y/B/LEAK/TST  1881GP  N35
 121VU HYDRAULIC/SOL VALVES/G/Y/PTU  1801GL  N34
 121VU FLIGHT CONTROLS/SEC3/SPLY  21CE3  Q19
 121VU FLIGHT CONTROLS/SEC2/SPLY  21CE2  Q18
 121VU FLIGHT CONTROLS/ELAC2/NORM/SPLY  15CE2  R20
 Subtask 29-00-00-865-055
 C. Open, safety and tag this(these) circuit breaker(s):
 ------PANEL  ------------------------------------------------------DESIGNATION  -------------------IDENT. LOCATION

 -------------------------------------------------------------------------------121VU HYDRAULIC/HYD POWER/Y 3803GX N30 123VU Y HYD/ELEC/PUMP 3802GX AB06 123VU Y HYD/ELEC/ELEC PUMP/NORM 3801GX AB03
 Subtask 29-00-00-860-056
 D. Aircraft Maintenance Configuration
 (1)
 Connect a ground hydraulic supply with a flowmeter to the ground test connections of the Yellow hydraulic system.

 (2)
 In the main landing gear compartment, disconnect the PTU isolation coupling (Ref. TASK 29-23-00-860-001).

 (3)
 Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

 (4)
 Set the ECAM system to on (Ref. TASK 31-60-00-860-001).


 1EFF : ALL 1 29-00-00Page 652 1 1 Aug 01/05R 1 1 1CES 1


 (5)
 On the ECAM control panel on the center pedestal, push the F/CTL pushbutton (P/B). Make sure the lower display unit (DU) shows the F/CTL page.

 (6)
 Pressurize the Yellow hydraulic system from the ground supply (Ref. TASK 29-10-00-863-002).

 (7)
 On the overhead panel 23VU, make sure that the ELAC 1 and SEC 1 pushbutton switches P/BSW are set to on (OFF and FAULT lights not on).

 (8)
 On the overhead panel 24VU, make sure that the ELAC 2, SEC 2, SEC 3 and FAC 2 P/BSW are set to on (OFF and FAULT lights not on).

 (9)
 On the overhead panel 40VU set the PTU P/BSW to OFF (the OFF light comes on).


 WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE
_______ CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE.
 (10)
 Operate the sidestick and rudder pedals to put the control surfaces associated with the Yellow hydraulic system in the 0 deg position (spoilers retracted).

 (11)
 Keep all of the control surfaces stopped in the 0 deg (retracted) position during measurement of internal leakage.


 NOTE : Do the checks of internal leakage with the hydraulic fluid at
____ its usual working temperature of between 20 deg.C (68.00 deg.F) and 60 deg.C (140.00 deg.F).
 4. Procedure
_________
 Subtask 29-00-00-280-061
 A. Check of the Internal Leakage of the Yellow Hydraulic System
 (1) Measurement of the Yellow system (complete) internal leakage
 (a)
 On the overhead maintenance panel 50VU, make sure that the HYD/LEAK MEASUREMENT VALVES/Y P/BSW is set to on (OFF light not on).

 (b)
 On the overhead panel 40VU, make sure that the PTU P/BSW is set to OFF (the OFF light is on).


 1EFF : ALL 1 29-00-00Page 653 1 1 Aug 01/05R 1 1 1CES 1


 (c) Monitor the flow shown on the ground supply flowmeter. It must not be more than 10.0 l.min (2.6416 USgal.mn).
 