29-12-44-960-001
29-12-45-610-001
29-12-45-960-001
29-12-51-000-001
29-12-51-400-001
29-13-44-610-001
29-13-44-960-001
29-13-45-610-001
29-13-45-960-001 R 29-10-00-991-009
3. Job Set-up
__________
Subtask 29-10-00-010-075
A. Get Access
Replacement of the Clogging Indicator (for corrective action)Servicing of the HP-Filter 2048GM (for corrective action)Replacement of the Clogging Indicator (for corrective action)Removal of the Electric Pump (2075GJ) (for corrective action)Installation of the Electric Pump (2075GJ) (for corrective action)Servicing of the LP-Filter (3002GM) (for corrective action)Replacement of the Clogging Indicator (for corrective action)Servicing of the HP-Filter (3048GM) (for corrective action)Replacement of the Clogging Indicator (for corrective action) Fig. 604
(1)
Open one main door of the main gear (Ref. TASK 32-12-00-010-001).
(2)
Open the access doors 195BB, 196BB, 197CB, 197FB.
4. Procedure
_________
R (Ref. Fig. 604/TASK 29-10-00-991-009)
Subtask 29-10-00-210-059
A. Do a Check of the Clogging Indicators of the Hydraulic System Filters
(1) Use the procedures that follow to look at the clogging indicators of these filters:
-
the low pressure (return) filter (1002GM) of the Green hydraulic system
-
the high pressure (delivery) filter (1048GM) of the Green hydraulic system
-
the case drain filter (2084GM) of the electric pump of the Blue hydraulic system
-
the low pressure (return) filter (2002GM) of the Blue hydraulic system
-
the high pressure (delivery) filter (2048GM) of the Blue hydraulic system
-
the low pressure (return) filter (3002GM) of the Yellow hydraulic system
-
the high pressure (delivery) filter (3048GM) of the Yellow hydraulic system
-
the (ground service) filter (1132GM) of the reservoir filling system
-
the reservoir pressurization filter of the reservoir pressurization unit (1360GM)
-
the water separator filter of the reservoir pressurization unit (1360GM).