R  (e) Turn the master keyway of the connector of the pressure switch 
R  (6) to the forward position. Tighten the clamp of the pressure 
R  switch (6). 
R  (f) Tighten the clamps of the hydraulic pressure hose (Ref. TASK 29-
R  11-49-400-002). 
R  CAUTION : USE A SECOND WRENCH TO APPLY COUNTERTORQUE TO THE UNION_______ 
R  WHEN YOU DISCONNECT/CONNECT HYDRAULIC LINES ON UNIONS. 
R  IF YOU USE THE SECOND WRENCH, YOU WILL NOT LOOSEN OR 
R  TIGHTEN THE UNION TOO MUCH. 
R  (g) TORQUE the line end fitting (7) to between 620 and 680 lbf.in 
R  (7.00 and 7.68 m.daN). 
R  (h) TORQUE the line end fitting (3) to between 215 and 245 lbf.in 
R  (2.42 and 2.76 m.daN). 
R  (i) Loosen the bolts (5) and make sure that the line (2) has no 
R  pre-tension. 
R  (j) TORQUE the bolts (5) to between 20 and 25 lbf.in (0.22 and 0.28 
R  m.daN) .

 

R  (3) Install the line (2) as given in the subsequent worksteps: 
R  - when you have not found pre-tension of the line (2) during the 
R  removal of the bolts (5) and the washers (4), 
R  - when it was not necessary to repair or replace the line (2). 
R  (a) Attach the clamps (1) with the bolts (5) and the washers (4). 
R  (b) TORQUE the bolts (5) to between 20 and 25 lbf.in (0.22 and 0.28 
R  m.daN). 
R  Subtask 29-10-00-790-052 
R  B. Test 
R  (1) Do an operational test of the Green hydraulic system (Ref. TASK 29-
R  11-00-710-001). 
R  (2) Do an operational test of the Yellow hydraulic system (Ref. TASK 29-
R  13-00-710-002). 
R  (3) During the dry motoring of the engines, make sure that there are no 
R  leaks from the hydraulic pressure switch line (2). 
R  (4) Make sure that the level of the hydraulic fluid in the Green and 
R  Yellow reservoir is correct. If necessary, fill the reservoir 
R  (Ref. TASK 12-12-29-611-001) or (Ref. TASK 12-12-29-611-002). 
R  5. Close-up________ 
R  Subtask 29-10-00-410-072 
R  A. Close Access 
R  (1) Remove the access platform(s). 
R  (2) Remove the container. 
R  (3) Make sure that the work area is clean and clear of tool(s) and other 
R  items. 
R  (4) Close the fan cowl doors (Ref. TASK 71-13-00-410-040). 
R  (5) Remove the warning notice(s).

 

 Subtask 29-10-00-865-079
 B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU HYDRAULIC/Y HYD/PUMP ENG2/MONG 3700GD Q37 121VU HYDRAULIC/Y HYD/PUMP ENG2/CTL 3701GD Q36 121VU HYDRAULIC/G HYD/PUMP ENG1/CTL 1701GK R35 121VU HYDRAULIC/G HYD/PUMP ENG1/MONG 1702GK R34 123VU Y HYD/ELEC/PUMP 3802GX AB06
R 123VU Y HYD/ELEC/ELEC PUMP/NORM 3801GX AB03


 TASK 29-10-00-210-002
 Check of the Clogging Indicators of the Hydraulic System Filters (Other than the two Case Drain Filters of the Engine-Driven Pumps)
 1. Reason for the Job
__________________
 Refer to the MPD TASK: 290000-05
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
29-11-00-710-001 
29-11-44-610-001 
R
 29-12-00-710-001 
R
 29-13-00-710-002 
R
 29-14-00-720-001 
29-14-41-610-002 
29-14-42-000-002 
29-14-42-400-002 
29-16-11-610-001 
32-12-00-010-001 
32-12-00-410-001 
R  29-11-44-610-001 

R  29-11-44-960-001 

R  29-11-45-610-001 

R  29-11-45-960-001 

R  29-12-43-610-001 

R  29-12-44-610-001 

Operational Test of the Green Hydraulic SystemServicing of the LP-Filter (1002GM)
Functional Check of Blue Electrical Pump Pressure by Reading ECAM Indication
Operational Test of the Yellow Hydraulic System
Functional Test of the Pressurizing System of the Hydraulic ReservoirsServicing of the Reservoir Pressurization FilterRemoval of the Filter Element of the Water SeparatorInstallation of the Filter Element of the Water SeparatorServicing of the HP-Filter 1132GMOpen the Main Gear Doors for AccessClose the Main Gear Doors after Access Servicing of the LP-Filter (1002GM) (for corrective action) Replacement of the Clogging Indicator (for corrective action) Servicing of the HP-Filter 1048GM (for corrective action) Replacement of the Clogging Indicator (for corrective action) Servicing of the Electric-Pump Case-Drain Filter (2084GM) (for corrective action) Servicing of the LP-Filter (2002GM) (for corrective action) -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM HYDRAULIC POWER 液压1(125)