-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
R 29-00-00-991-001 **ON A/C 401-499, Fig. 601
R R 29-00-00-991-001-A Fig. 601A **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
R 29-00-00-991-002 **ON A/C 401-499, Fig. 602
R R 29-00-00-991-002-A Fig. 602A **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
R 29-00-00-991-003 **ON A/C 401-499, Fig. 603
R R 29-00-00-991-003-A Fig. 603A **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
R 29-00-00-991-004 **ON A/C 401-499, Fig. 604
R 29-00-00-991-004-A Fig. 604A
R **ON A/C ALL
3. Job Set-up
__________
Subtask 29-00-00-010-051
A. Get Access
(1)
Open the access door 197CB.
(2)
Open the right main door of the main gear (Ref. TASK 32-12-00-010-001).
Subtask 29-00-00-865-050
B. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU FLIGHT CONTROLS/ELAC1/NORM/SPLY 15CE1 B11 49VU FLIGHT CONTROLS/SEC1/NORM/SPLY 21CE1 B08 49VU AUTO FLT/FAC1/28VDC 5CC1 B04 49VU AUTO FLT/FAC1/26VAC 14CC1 B03 105VU FLIGHT CONTROLS/ELAC2/STBY SPLY 16CE2 A02 105VU FLT CTL/ELAC1/STBY SPLY 16CE1 A01 105VU FLT CTL/SEC1/STBY SPLY 22CE B01 121VU HYDRAULIC/SOL VALVES/G/Y/B/LEAK/TST 1881GP N35 121VU HYDRAULIC/SOL VALVES/G/Y/PTU 1801GL N34 121VU FLIGHT CONTROLS/SEC3/SPLY 21CE3 Q19 121VU FLIGHT CONTROLS/SEC2/SPLY 21CE2 Q18 121VU FLIGHT CONTROLS/ELAC2/NORM/SPLY 15CE2 R20
Subtask 29-00-00-865-079
C. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU L/G/LGCIU/SYS1/NORM 1GA C09 121VU HYDRAULIC/LGCIU/SYS2 2GA Q35 121VU HYDRAULIC/LGCIU/SYS1/GRND SPLY 52GA Q34 121VU HYDRAULIC/G HYD/PUMP ENG1/CTL 1701GK R35 121VU HYDRAULIC/G HYD/PUMP ENG1/MONG 1702GK R34
Subtask 29-00-00-860-052
D. Aircraft Maintenance Configuration
(1)
Disconnect the connector 49GA-A from the safety valve 49GA to de-energize the safety valve 49GA (valve closed).
(2)
Install a PLUG - BLANKING on the disconnected electrical connector.
(3)
Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1GA, 2GA, 52GA, 1701GK, 1702GK
(4)
Connect a ground hydraulic supply with a flowmeter to the ground test connections of the Green hydraulic system.
(5)
Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).
(6)
Set the ECAM system to ON (Ref. TASK 31-60-00-860-001).
(7)
On the ECAM control panel on the center pedestal, push the F/CTL pushbutton (P/B). Make sure that the lower display unit (DU) shows the F/CTL page.
(8)
In the main gear compartment, disconnect the PTU isolation coupling (Ref. TASK 29-23-00-860-001).
(9)
Pressurize the Green hydraulic system from the ground supply (Ref. TASK 29-10-00-863-001).
(10)
On the overhead panel 23VU, make sure that the ELAC 1, SEC 1 and FAC 1 pushbutton switches (P/BSW) are set to on (the OFF and FAULT lights not on).
(11)
On the overhead panel 24VU, make sure that the ELAC 2, SEC 2 and SEC 3 P/BSW are set to on (the OFF and FAULT lights not on).
(12)
On the overhead panel 40VU, set the PTU P/BSW to OFF (the OFF light comes on).
(13)
Operate the flight control surfaces. WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM HYDRAULIC POWER 液压1(77)