Blue Hydraulic System - Central Section Figure 605A/TASK 29-00-00-991-005-A
R 1EFF : 062-099, 106-149, 151-199, 204-299, 1 29-00-00Page 639 1301-399, 401-499, 1Aug 01/05 1 1 1CES 1
Blue Hydraulic System - Rear Section
Figure 606/TASK 29-00-00-991-006
1EFF : 001-049, 051-061, 101-105, 201-203, 1 29-00-00Page 640 1 1 Aug 01/05R 1 1 1CES 1
Blue Hydraulic System - Rear Section
Figure 606A/TASK 29-00-00-991-006-A
R 1EFF : 062-099, 106-149, 151-199, 204-299, 1 29-00-00Page 641 1301-399, 401-499, 1Aug 01/05 1 1 1CES 1 **ON A/C ALL
(a)
On the overhead maintenance panel 50VU, make sure that the HYD/LEAK MEASUREMENT VALVES/B P/BSW is set to off (OFF light is on).
(b)
If the P/BSW is not set to off (OFF light not on);
-stop the supply of pressure to the aircraft,
-wait for the pressure in the system to decrease,
-set the P/BSW to off (OFF light comes on),
-increase the supply of pressure to the same pressure as before.
(c)
In the Blue system compartment, turn the REAR manual selector valve to the ON position.
(d)
Monitor the flow shown on the ground supply flowmeter. It must not be more than 5.0 l.min (1.3208 USgal.mn).
(e)
In the Blue system compartment, turn the REAR manual selector valve to the OFF position.
(4) Measurement of the Blue system (left wing section) internal leakage
**ON A/C 001-049, 051-061, 101-105, 201-203,
(Ref. Fig. 607/TASK 29-00-00-991-007)
R **ON A/C 062-099, 106-149, 151-199, 204-299, 301-399, 401-499,
(Ref. Fig. 607A/TASK 29-00-00-991-007-A)
**ON A/C ALL
(a)
On the overhead maintenance panel 50VU, make sure that the HYD/LEAK MEASUREMENT VALVES/B P/BSW is set to off (OFF light is on).
(b)
If the P/BSW is not set to off (OFF light not on):
-stop the supply of pressure to the aircraft,
-wait for the pressure in the system to decrease,
-set the P/BSW to off (OFF light comes on),
-increase the supply of pressure to the same pressure as before.
Blue Hydraulic System - Left Wing Section
Figure 607/TASK 29-00-00-991-007
R 1EFF : 001-049, 051-061, 101-105, 201-203, 1 29-00-00Page 643 1 1 Aug 01/05 1 1 1CES 1
Blue Hydraulic System - Left Wing Section Figure 607A/TASK 29-00-00-991-007-A
R 1EFF : 062-099, 106-149, 151-199, 204-299, 1 29-00-00Page 644 1301-399, 401-499, 1Aug 01/05 1 1 1CES 1
(c)
In the Blue system compartment, turn the LH WING manual selector valve to the ON position.
(d)
Monitor the flow shown on the ground supply flowmeter. It must not be more than 2.2 l.min (0.5811 USgal.mn).
(e)
In the Blue system compartment, turn the LH WING manual selector valve to the OFF position.
(5) Measurement of the Blue system (right wing section) internal leakage
**ON A/C 001-049, 051-061, 101-105, 201-203,
(Ref. Fig. 608/TASK 29-00-00-991-008)
R **ON A/C 062-099, 106-149, 151-199, 204-299, 301-399, 401-499,
(Ref. Fig. 608A/TASK 29-00-00-991-008-A)
**ON A/C ALL
(a)
On the overhead maintenance panel 50VU, make sure that the HYD/LEAK MEASUREMENT VALVES/B P/BSW is set to off (OFF light is on).
(b)
If the P/BSW is not set to off (OFF light not on);
-stop the supply of pressure to the aircraft,
-wait for the pressure in the system to decrease,
-set the P/BSW to off (OFF light comes on),
-increase the supply of pressure to the same pressure as before.
(c)
In the Blue system compartment, turn the RH WING manual selector valve to the ON position.
(d)
Monitor the flow shown on the ground supply flowmeter. It must not be more than 2.2 l.min (0.5811 USgal.mn).
(e)
In the Blue system compartment, turn the RH WING manual selector valve to the OFF position.
Blue Hydraulic System - Right Wing Section
Figure 608/TASK 29-00-00-991-008
R 1EFF : 001-049, 051-061, 101-105, 201-203, 1 29-00-00Page 646 1 1 Aug 01/05 1 1 1CES 1
Blue Hydraulic System - Right Wing Section
Figure 608A/TASK 29-00-00-991-008-A
R 1EFF : 062-099, 106-149, 151-199, 204-299, 1 29-00-00Page 647 1301-399, 401-499, 1Aug 01/05 1 1 1CES 1 (6) Permitted leakage rates of the components
(a) The maximum internal leakage permitted for components related to the Blue hydraulic system is:
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM HYDRAULIC POWER 液压1(82)