7.3.4 Distorted Output
7.3.5 No Output and no lights on front panel
7.3.6 No output, but front panel controller is active.
7.3.1 Excessive Output Voltage
CAUSE SOLUTION
External sense not connected(If used) Connect external sense wires on the rear
panel from TB1-1 to TB1-2 and from TB1-
3 to TB1-4
7.3.2 Poor Output Voltage Regulation
CAUSE SOLUTION
Unit is overloaded Remove overload
Unit is programmed to wrong voltage
range.
Select correct voltage range.
Input line has fallen below spec. limit. Check input supply voltage.
California Instruments 98
User Manual Compact i/iX Series
7.3.3 Overload Light is On
CAUSE SOLUTION
Unit is overloaded Remove overload or check CL setting
Unit is switched to high voltage range. Select correct voltage range.
7.3.4 Distorted Output
CAUSE SOLUTION
Power source is grossly overloaded. Reduce load
The crest factor of the load exceeds 3:1. Reduce load current peaks by reducing
load.
7.3.5 No Output and No Lights on Front Panel
CAUSE SOLUTION
Input switched off. Switch unit on.
No input power. Ensure power is present at AC input
terminal block.
Incorre
input. Check position of voltage selector
switch on rear panel.
ct input voltage 230V applied to a unit configured for 115V
7.3.6 No Output But Front Panel controller is active
CAUSE SOLUTION
“OUTPUT ON” button is turned off. Press OUTPUT ON so that “ON” LED is
lit.
Current limit programmed down or to zero. Program current limit higher.
Voltage programmed down or to zero. Turn amplitude control up.
California Instruments 99
User Manual Compact i/iX Series
7.4 Self test
A self test can be performed over the bus by sending the *TST? query command. The self-test will run
until the first error is encountered and terminate. The response to the query will either be the first
0 if no error was found. (Self-test passed).
To execute a self-test, the IEEE-488, LAN or USB interface must be used. The iXCGui command selftest
window can be used to send the *TST? Command. See the section 9 for possible self test error
es.
7.5 Advanced Troubleshooting.
error encountered or
codes and messag
WARNING: Do not connect 230V AC input to a unit set for 115V input, the result
could be a severely damaged unit.
CAUTION:
SE
VOLTAGES UP TO 230 VAC AND 500 VDC ARE PRESENT IN CERTAIN
CTIONS OF THIS POWER SOURCE.
WARNING: THIS EQUIPMENT GENERATES POTENTIALLY LETHAL VOLTAGES.
DEATH ON CONTACT MA SONNEL FAIL TO OBSERVE SAFETY
PRECAUTIONS. DO NOT TOUCH ELECTRONIC CIRCUITS WHEN POWER IS APPLIED
Y RESULT IF PER
Switch Off Un
itch off each cuit br om
unit.
its
Sw
the
unit at the cir eaker on the front panel as well as removing the input power fr
WARNING: Wait 10 minutes for all internal capacitors to discharge.
Removing Co
move the sc ng the to
tial Inspecti
ke a visual i n of the unit nectors are properly mated and there are no
se wires.
ver
Re rews securi p cover and remove it.
Ini on
Ma nspectio and ensure all the con
loo
California Instruments 100
User Manual Compact i/iX Series
7.6 Amplifier Module Data
This section lists the various connectors and interface pin outs to the 6005-400-1 amplifier module.
7.6.1 CONTROL BOARD
7.6.1.1 J1 - LV POWER
PINS NAME DESCRIPTION
1,2,3 +24V_FAN +12.0 Vdc to +24.0 Vdc @ 200 mAdc for module fan. Voltage is
externally controlled according to output current.
4,5,6 FAN_COM Return for +24V_FAN
7,8 +15G +15 Vdc +/- 0.5Vdc @ 450 mAdc for gate drive
9,10 G_COM Return for +15G
11,12 +15LV +15 Vdc +/- 0.5Vdc @ 150 mAdc for control circuits
13,14 LV_COM Return for +15LV and –15LV
15,16 -15_LV -15Vdc +/-0.5Vdc @ 100 mAdc for control circuits
7.6.1.2 J5 - FAN
PINS NAME DESCRIPTION
1 FAN_COM Return for fan
2 +24V_FAN DC voltage for fan
7.6.1.3 J6 - E/A IN/OUT
PINS NAME DESCRIPTION
1 E/A COM Return for E/A IN/OUT
2 E/A IN/OUT Error amplifier signal from master module to parallel auxiliary
modules
7.6.1.4 J2 - CONTROL SIGNALS
PINS NAME DESCRIPTION
1 A_COM Analog common
2 A_SIG_HI Phase A oscillator signal, 16 Hz to 1 kHz, 0 – 5.3 Vac
3 B_SIG_HI Phase B oscillator signal, values same as A_SIG_HI
4 C_SIG_HI Phase C oscillator signal, values same as A_SIG_HI
5 SCOM Signal common for A/B/C_SIG_HI
6 DCOM Digital logic common
7 LO_RNG
Range, TTL HI = High Voltage Range
Low Range control signal, input to module, TTL LO = Low Voltage
8 /AMP_FLT Amplifier fault indicator signal, output from module, open collector,
 