(RST). Factory default
the factory settings.
Note that to use REG0 for power-on default,
the contents o
programmed first. See section 4.2.8. If an
empty register is selected, the power source
will revert back to RST (factory setting).
CONTROL MAST
AUX ST
This is an information-only field that displays
the controller operation mode. For a single
stand-alone iX unit, the mode is always MA
(Master).
Alternatively, the auxiliary mode may be
detected if the system interface cable at the
rear panel is plugged in and connected to
another i/iX unit. In AUX mode, the AC source
is controlled by another unit (Master unit). The
controller will be disabled and has no control
over the amplifiers, the measurements or any
California Instruments 69
User Manual Compact i/iX Series
ENTRY DESCRIPTION
other fun
power indicating it is in Auxiliary mode. You
can press any key to get in the menus but no
control is possible.
ction. A message will be displayed at
LANGUAGE SCPI
ABLE
s for Programamble Instruments). If
Displays the active programming command
language syntax selection. Default for
compact i/iX series is SCPI (Standard
command
the –ABL option is installed, the ABLE (Atlas
Based Language Extension) syntax can be
selected. See programming manual for details
on use either syntax.
SYSTEM 1501iX
00 or
This field is not user controlled. It merely
indicates the configuration of the power
system.
If the multi-box option (-MB) is installed, this
field can be changed between 750, 15
3000. Set this field to the correct power level
for the configured system using the shuttle:
Unit(s) Setting
751i/iX 751i / 751iX
1501i/iX 1501i / 1501iX
2 x 751i/iX 1501i / 1501iX
2 x 1501i/iX 3001i / 3001iX
To reconfigure an existing system on which
the MB option was not configured, contact
California Instruments customer support
(support@calinst.com).
LANetwork LAN r
Nu In
If the –LAN option is installed; pressing Ente
while the cursor is on the LANetwork entry
provides access to the LAN interface setting
screens listed below.
ote: These screens require firmware 0.25 or higher. To
pdate older firmware revisions, contact California
struments customer support (support@calinst.com) or
check CI website.
IP Address Displays the IP address setting. This value
can be changed by pressing the SET key and
entering a new value from the keypad. Use
the numeric data pad to enter each field. To
move between the four fields, use the decima
point key on the keypad.
To set a fixed IP address, press SET and
enter the desired IP address. To set the uni
DHCP mode, press SET and enter all zeros
l
t to
T
(0.0.0.0) as the IP address and cycle power
two times. The obtained IP address will be
displayed after the second power on. For the
DHCP setting to work however, the unit MUS
be connected to a network with a DHCP
California Instruments 70
User Manual Compact i/iX Series
ENTRY DESCRIPTION
server.
Any change to this value will NOT take effec
until after powe
t
r on the unit has been cycled.
When changing mode from static IP to DHCP,
it is necessary to cycle power on the unit
twice, once to change mode and again to
obtain and display a new IP address from the
network.
MAC Address Displays the network Media Acces Control
address. This value is fixed and cannot be
changed. The same MAC is normally printed
on the model serial tag. The MAC address is
shown as six hexadecimal numbers separated
by a colon, e.g. 00:20:4A:9A:02:FD. Note that
the leading ‘0’ is never visible due to the
maximum number of LCD characters per line.
Note: If the MAC Address displayed is
corrupted or does not match the serial tag, there
may have been a problem retrieving the LAN
port settings. To recover, turn on power to the
unit while holding down the SET key. This will
allow the unit to boot without attempting to
collect the IP settings. You can then set the
required IP values. [See IP Address above].
GWAddress Gateway address setting. A default gateway
is a node (a router) on a computer network
that serves as an access point to another
network.
This value can be changed by pressing the
SET key and entering a new value from the
keypad. Use the numeric data pad to enter
each field. To move between the four fields,
use the decimal point key on the keypad.
Any change to this value will NOT take effect