v.
Install jumper wire from Connector D3192 Pin 2 to Pin 3. Wire to be made from BMS13-60, Type 2, Class 1, 20 gauge and installed per SWPM (D6-54446).
vi. Reestablish power by closing circuit breaker C1023.
vii.Pressurize the left, right, and centre hydraulic systems. Refer AMM 29-11-00 10) Use an air data test set to simulate 200 KCAS on the right air data computer (R-ADC). 11) Select FLAPS UP 12) Use an air data test set to simulate and maintain 300 KCAS on the right air data computer (R-
ADC).
13) Place the SPEEDBRAKE handle to the full UP position
14) Use an air data test set to simulate and maintain 340 KCAS on the right air data computer (R-
ADC). Verify the following:
.
SPEEDBRAKE handle does not move.
.
all three lights on the SAC module are extinguished
.
amber AUTO SPEEDBRAKE EICAS message is extinguished
. amber AUTO SPDBRK message on overhead panel is extinguished 15) Use an air data test set to simulate and maintain 300 KCAS on the right air data computer (R-
ADC). 16) Input 222,000 lbs (100,697 kg) in the FMC.
Aviation Partners Boeing
757-200 MAINTENANCE MANUAL SUPPLEMENT Part II
NOTE:
Values in (x) represent x1000kg. Typed values below are arbitrary, but will work for all aircraft. Any summation of FUEL weight value from 0-123, with ZFW value from 100-220 to give 222 GR WT is acceptable]
a.
When the MENU page is displayed on either CDU, press LSK 1L (FMC) on that CDU.
b.
PRESS, the INIT/REF button on CDU-1.
c.
PRESS, LSK 6L (INDEX) on CDU-1.
d.
PRESS, 3L (PERF) on CDU-1.
e.
TYPE, 42 (19.1) on CDU-1
f.
PRESS, LSK 2L (FUEL) on CDU-1
g. 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:757-200 MAINTENANCE MANUAL SUPPLEMENT Part II 维护手册补充(15)