32-09-08
ALL ú ú 02 Page 202 ú Dec 20/92
A
757
MAINTENANCE MANUAL
ADJUST THE POSITION OF THE TORSION LINK SHIM (SUPPORTS THE WEIGHT OF THE TORSION LINK) UNTIL THE INCLINOMETER INDICATES 31.5 DEGREES FROM VERTICAL OR THE REFERENCE SENSOR GAP IS 0.09 |0.01 INCH.
Sensor Gap Measurement
Figure 202
32-09-08
ALL ú ú 02 Page 203 ú Sep 20/94
E48191
A
757 MAINTENANCE MANUAL
S 862-006
CAUTION: WRITE DOWN THE COLOR CODE AND THE PIN LOCATIONS OF THE SENSOR
_______ WIRES BEFORE YOU DISCONNECT THEM. THIS WILL MAKE THE INSTALLATION OF THE NEW SENSOR WIRES EASIER AND WILL PREVENT THE MALFUNCTION OF THE AIR/GROUND RELAY SYSTEM.
(3)
Put a tag with the color code and the pin locations on the sensor wires.
S 032-007
(4)
Use a pin extraction tool to remove the sensor wires from the terminal block in the panel.
S 862-008
(5)
Put a line on the sensor wires to make the installation easier.
S 032-011
(6)
Disconnect the conduit coupling nut (5) from the sensor (3).
S 032-012
(7)
Remove the sensor mounting screws (7 and 10).
S 022-013
(8)
Remove the sensor (3) and pull the sensor wires from the conduit (2). Do not pull the lines fully out.
NOTE: The wire bundle ties can be cut to remove the sensor wires.
____
TASK 32-09-08-402-014
3. Install the Nose Landing Gear Not Compressed Sensor (Fig. 201)___________________________________________________
A. Equipment
(1) Pin Insertion/Extraction Tool
Part on Crimp Tool Kit - DMC 567
Daniels Manufacturing Corp.
526 Thorpe Road
Orlando, Forida 32824
32-09-08
ALL ú ú 02 Page 204 ú Mar 20/96
A
757 MAINTENANCE MANUAL
B. Parts
~.............................................................................. | MM | | IPC | ................. ............................ | FIG | ITEM | NOMENCLATURE | SUBJECT | FIG | ITEM | ................................................................................ | 201 | 3 | Sensor | 32-09-08 | 01 | 15 | | | 6 | Shim | | | 35 | | | 7 | Screw | | | 25 | | | 8 | Nut | | | 30 | | | 10 | Screw | | | 20 | 2.......….......…...................................…...........….....…........1
C. References
(1)
Chapter 20, Standard Wiring Practices Manual (SWPM)
D.
Access
(1)
Location Zones
711 Nose Landing Gear
E.
Install the Sensors
S 432-050
CAUTION:_______DO NOT DROP OR HIT THE SENSORS. YOU CAN CAUSE DAMAGE TO THE
INTERNAL COMPONENTS OF THE SENSORS AND CAUSE A FAILURE OF THE
AIR/GROUND RELAY SYSTEM.
(1)
Twist the sensor wires together.
S 432-049
(2)
If you install a new sensor, do the steps that follow:
(a)
Put a line on the sensor wires.
(b)
Put the wires through the conduit (2) to the terminal block in P62 (1) or P63 (4).
(3)
Pull the sensor wire through the conduit into the panel box.
S 432-052
(4)
Tighten with your hand the conduit coupling nut (5) to the sensor (3).
S 862-023
(5)
If you install a new sensor, cut the sensor wire to the correct length.
(a) 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:757 AMM 飞机维护手册 起落架 CHAPTER 32 - LANDING GEAR 1(66)