S 865-032
(25)
Erase the EICAS memory.
S 865-033
(26)
Make sure the AIR/GND DISAGREE message is not shown on the EICAS.
S 865-077
(27)
Make sure the AIR/GND SYS message does not show on the EICAS.
S 965-034
(28)
Install or remove the switch actuators or deactuators on the proximity sensors as shown below: ~............................................................ | SENSOR | LOCATION | ACTUATOR | DEACTUATOR | .............................................................. | S10068 | Nose Gear | Remove | - -| 2.........…................…..............…..................1
S 865-035
(29)
Make sure the NOSE A/G DISAGREE message is shown on the EICAS. Permit 10 seconds for the message to come into view.
(30)
Make sure the NOSE A/G SYS message shows on the EICAS.
S 965-036
(31)
Install or remove the switch actuators or deactuators on the proximity sensors as shown below: ~............................................................ | SENSOR | LOCATION | ACTUATOR | DEACTUATOR | .............................................................. | S10062 | Left Main Gear | - -| Install | 2.........…................…..............…..................1
S 865-064
32-09-02
ALL ú ú 07 Page 509 ú Jan 28/00
A
757
MAINTENANCE MANUAL
S 765-037
(32)
Use a volt/ohmmeter to measure the voltage between pins 6 (+ voltage) and 12 (ground). The connectors to be measured are in column A of Tables 1 and 2. The measured voltage of each connector must be the same as the voltage shown in column E of Table 1 and column B of Table 2.
S 965-038
(33)
Install or remove the switch actuators or deactuators on the proximity sensors as shown below: ~............................................................ | SENSOR | LOCATION | Actuator | DEACTUATOR | .............................................................. | S10062 | Left Main Gear | - -| Remove | .............................................................. | S10060 | Right Main Gear| - -| Install | 2.........…................…..............…..................1
S 765-039
(34)
Use a volt/ohmmeter to measure the voltage between pins 6 (+ voltage) and 12 (ground). The connectors to be measured are in column A of Tables 1 and 2. The measured voltage of each connector must be the same as the voltage shown in column E of Table 1 and column B of Table 2.
S 965-040
(35)
Install or remove the switch actuators or deactuators on the proximity sensors as shown below: ~............................................................ | SENSOR | LOCATION | ACTUATOR | DEACTUATOR | .............................................................. | S10062 | Left Main Gear | - -| Install | 2.........…................…..............…..................1
S 865-041
(36)
Make sure the AIR/GND DISAGREE message is shown on the EICAS. Permit 10 seconds for the message to come into view.