• 热门标签

当前位置: 主页 > 航空资料 >

时间:2011-10-30 09:32来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 S 965-031
 (24)
 Install or remove the switch actuators or deactuators on the proximity sensors as shown below: ~............................................................ | SENSOR | LOCATION | ACTUATOR | DEACTUATOR | .............................................................. | S10064 | Left Main Gear | - -| Remove | .............................................................. | S10059 | Right Main Gear| - -| Remove | 2.........…................…..............…..................1

 S 865-032

 (25)
 Erase the EICAS memory.

 S 865-033

 (26)
 Make sure the AIR/GND DISAGREE message is not shown on the EICAS.

 S 865-077

 (27)
 Make sure the AIR/GND SYS message does not show on the EICAS.

 S 965-034

 (28)
 Install or remove the switch actuators or deactuators on the proximity sensors as shown below: ~............................................................ | SENSOR | LOCATION | ACTUATOR | DEACTUATOR | .............................................................. | S10068 | Nose Gear | Remove | - -| 2.........…................…..............…..................1

 S 865-035

 (29)
 Make sure the NOSE A/G DISAGREE message is shown on the EICAS. Permit 10 seconds for the message to come into view.

 (30)
 Make sure the NOSE A/G SYS message shows on the EICAS.

 S 965-036

 (31)
 Install or remove the switch actuators or deactuators on the proximity sensors as shown below: ~............................................................ | SENSOR | LOCATION | ACTUATOR | DEACTUATOR | .............................................................. | S10062 | Left Main Gear | - -| Install | 2.........…................…..............…..................1


 S 865-064
 

 32-09-02
 ALL  ú ú 07 Page 509 ú Jan 28/00
 
A

757
MAINTENANCE MANUAL

 S 765-037
 (32)
 Use a volt/ohmmeter to measure the voltage between pins 6 (+ voltage) and 12 (ground). The connectors to be measured are in column A of Tables 1 and 2. The measured voltage of each connector must be the same as the voltage shown in column E of Table 1 and column B of Table 2.

 S 965-038

 (33)
 Install or remove the switch actuators or deactuators on the proximity sensors as shown below: ~............................................................ | SENSOR | LOCATION | Actuator | DEACTUATOR | .............................................................. | S10062 | Left Main Gear | - -| Remove | .............................................................. | S10060 | Right Main Gear| - -| Install | 2.........…................…..............…..................1

 S 765-039

 (34)
 Use a volt/ohmmeter to measure the voltage between pins 6 (+ voltage) and 12 (ground). The connectors to be measured are in column A of Tables 1 and 2. The measured voltage of each connector must be the same as the voltage shown in column E of Table 1 and column B of Table 2.

 S 965-040

 (35)
 Install or remove the switch actuators or deactuators on the proximity sensors as shown below: ~............................................................ | SENSOR | LOCATION | ACTUATOR | DEACTUATOR | .............................................................. | S10062 | Left Main Gear | - -| Install | 2.........…................…..............…..................1

 S 865-041

 (36)
 Make sure the AIR/GND DISAGREE message is shown on the EICAS. Permit 10 seconds for the message to come into view.


 


 