S 765-020
(11)
Use a volt/ohmmeter to measure the voltage between pins 6 (+ voltage) and 12 (ground). The connectors to be measured are in column A of Tables 1 and 2. The measured voltage of each connector must be the same as the voltage shown in column D of Table 1 and column B of Table 2.
S 965-021
(12)
Install or remove the switch actuators or deactuators on the proximity sensors as shown below: ~............................................................ | SENSOR | LOCATION | ACTUATOR | DEACTUATOR | .............................................................. | S10068 | Nose Gear | Install | - -| .............................................................. | S10064 | Left Main Gear| - -| Install | 2.........…................…..............…..................1
S 765-022
(13)
Use a volt/ohmmeter to measure the voltage between pins 6 (+ voltage) and 12 (ground). The connectors to be measured are in column A of Tables 1 and 2. The measured voltage of each connector must be the same as the voltage shown in column D of Table 1 and column E of Table 2.
S 965-023
(14)
Install or remove the switch actuators or deactuators on the proximity sensors as shown below: ~............................................................ | SENSOR | LOCATION | ACTUATOR | DEACTUATOR | .............................................................. | S10064 | Left Main Gear | - -| Remove | .............................................................. | S10059 | Right Main Gear| - -| Install | 2.........…................…..............…..................1
S 765-024
(15)
Use a volt/ohmmeter to measure the voltage between pins 6 (+ voltage) and 12 (ground). The connectors to be measured are in column A of Tables 1 and 2. The measured voltage of each connector must be the same as the voltage shown in column D of Table 1 and column E of Table 2.
32-09-02
ALL ú ú 02 Page 507 ú May 28/99
A
757
MAINTENANCE MANUAL
S 965-025
(16)
Install or remove the switch actuators or deactuators on the proximity sensors as shown below: ~............................................................ | SENSOR | LOCATION | ACTUATOR | DEACTUATOR | .............................................................. | S10064 | Left Main Gear | - -| Install | 2.........…................…..............…..................1
S 865-026
(17)
Erase the EICAS memory.
S 865-027
(18)
Make sure the NOSE A/G DISAGREE message is not shown on the EICAS.
S 865-073
(19)
Make sure the NOSE A/G SYS message does not show on the EICAS.
S 765-028
(20)
Use a volt/ohmmeter to measure the voltage between pins 6 (+ voltage) and 12 (ground). The connectors to be measured are in column A of Tables 1 and 2. The measured voltage of each connector must be the same as the voltage shown in column D of Table 1 and column C2 of Table 2.
S 865-029
(21)
Make sure the AIR/GND DISAGREE message is shown on the EICAS. Permit 10 seconds for a message to come into view.
(22)
Make sure the AIR/GND SYS message shows on the EICAS.
S 865-030
(23)
Move the EICAS computer select switch to the R position.
(a)
Make sure the AIR/GND DISAGREE message is shown on the EICAS.
S 865-075
32-09-02
ALL ú ú 08 Page 508 ú Jan 28/00
A
757
MAINTENANCE MANUAL
(b) Make sure the AIR/GND SYS message shows on the EICAS. 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:757 AMM 飞机维护手册 起落架 CHAPTER 32 - LANDING GEAR 1(41)