 ALL  ú ú 05 Page 510 ú May 28/99
 
A

757
MAINTENANCE MANUAL

 S 865-066
 (37)
 Make sure the AIR/GND SYS message shows on the EICAS.

 S 865-042

 (38)
 Move the EICAS computer select switch to the L position.

 (a)  
Make sure the AIR/GND DISAGREE message is shown on the EICAS.

 (b)  
Make sure the AIR/GND SYS message shows on the EICAS.

 (c)  
AIRPLANES WITH S242N701-1001 EICAS COMPUTERS; Make sure the AIR/GND SYS message shows on the EICAS.


 S 765-043
 (39)
 Use a volt/ohmmeter to measure the voltage between pins 6 (+ voltage) and 12 (ground). The connectors to be measured are in column A of Tables 1 and 2. The measured voltage of each connector must be the same as the voltage shown in column C2 of Table 1 and column B of Table 2.

 S 965-044

 (40)
 Install or remove the switch actuators or deactuators on the proximity sensors as shown below: ~............................................................ | SENSOR | LOCATION | ACTUATOR | DEACTUATOR | .............................................................. | S10068 | Nose Gear | Install | - -| 2.........…................…..............…..................1

 S 765-045

 (41)
 Use a volt/ohmmeter to measure the voltage between pins 6 (+ voltage) and 12 (ground). The connectors to be measured are in column A of Tables 1 and 2. The measured voltage of each connector must be the same as the voltage shown in column C2 of Table 1 and column D of Table 2.

 (42)
 Remove the pressure from the left hydraulic system (Ref 29-11-00).


 S 865-046
 

 32-09-02
 ALL  ú ú 01 Page 511 ú Sep 28/01
 
A

757
MAINTENANCE MANUAL

 S 875-047
 WARNING:_______ BE CAREFUL WHEN YOU BLEED THE HYDRAULIC FLUID.  THERE IS
 PRESSURE ON THE HYDRAULIC FLUID.  WHEN YOU BLEED THE
 PRESSURIZED HYDRAULIC FLUID, IT CAN CAUSE INJURY TO PERSONS.

 CAUTION: PUT A FUNNEL ON THE BLEED PORT ON THE TRUCK TILT POSITIONER OF
_______ THE MAIN LANDING GEAR. THE HYDRAULIC FLUID WILL FLOW APPROXIMATELY THREE FEET FROM THE BLEED PORT. THE HYDRAULIC FLUID CAN CAUSE DAMAGE TO THE EQUIPMENT.
 (43)
 Use the bleed ports on the truck tilt positioners of the main landing gear, to remove the pressure from the positioners.

 S 765-048

 (44)
 Use a volt/ohmmeter to measure the voltage between pins 6 (+ voltage) and 12 (ground). The connectors to be measured are in column A of Tables 1 and 2. The measured voltage of each connector must be the same as the voltage shown in column C2 of Table 1 and column C1 of Table 2.

 S 965-049

 (45)
 Install or remove the switch actuators or deactuators on the proximity sensors as shown below: ~............................................................ | SENSOR | LOCATION | ACTUATOR | DEACTUATOR | .............................................................. | S10060 | Right Main Gear| - -| Remove | .............................................................. | S10062 | Left Main Gear | - -| Remove | 2.........…................…..............…..................1

 (46)
 Pressurize the left hydraulic system (Ref 29-11-00).


 S 865-050
 

 32-09-02
 ALL  ú ú 05 Page 512 ú Jan 28/00
 
A

757
MAINTENANCE MANUAL

 S 865-051
 (47)
 Erase the EICAS memory.

 S 865-052

 (48)
 Remove the pressure from the left hydraulic system (Ref 29-11-00).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 起落架 CHAPTER 32 - LANDING GEAR 1(43)