(2)
Access Panel
198GR RAT Compartment
B. Procedure
S 226-003
(1) Examine the RAT with the wear limits in Figures 601 and 602.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-21-01
ALL ú ú 02 Page 601 ú May 28/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL
4 4
4 4
ASEE RAM AIR TURBINE (RAT) 10 11 9 2
6 8 5 3 6 1
3
COVER 5
TURBINE
BLADE
13 (2 LOCATIONS)
12
RAT
COMPARTMENT
DOOR
0.500
TURBINE
HUB
FWD
TURBINE HYDRAULIC
BLADE PUMP
0.125
RAM AIR TURBINE (RAT) TURBINE BLADES AND HUB
A B
Ram Air Turbine (RAT) Inspection
Figure 601 (Sheet 1)
E03830
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-21-01
ALL ú ú 01 Page 602 ú Mar 20/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL
3.000 |0.010 INCHES
7.656 |0.010 INCHES
1.400 |0.010 INCHES
0.600 |0.010 INCHES
THREE OR LESS DENTS THAT ARE SMALLER THAN 0.075 |0.025 INCH DEEP AND 0.500 INCH IN DIAMETER ARE PERMITTED PER COVER, DENTS THAT ARE LARGER THAN 0.100 INCH DEEP AND 0.500 INCH IN DIAMETER ARE NOT PERMITTED.
NICKS ON LEADING AND TRAILING EDGES IN AREA
THAT ARE LARGER THAN 0.005 INCH DEEP AND
0.040 INCH WIDE ARE NOT PERMITTED. SCRATCHES ON THE SURFACES OF AREA
THAT ARE LARGER THAN 0.005 INCH DEEP AND 0.040 INCH WIDE AND 1.500 INCHES LONG ARE NOT PERMITTED.
NICKS AND SCRATCHES IN AREA
THAT ARE LARGER THAN 0.040 INCH DEEP AND 0.080 INCH WIDE ARE NOT PERMITTED.
DENTS THAT ARE MORE THAN 5% OF TURBINE BLADE THICKNESS OR LARGER THAN 0.040 INCH IN AREA
ARE NOT PERMITTED.
NICKS AND DENTS ON LEADING AND TRAILING EDGES IN AREA
THAT ARE MORE THAN 2% OF THE LOCAL
CHORD ARE NOT PERMITTED.
BLADE TIP CORNERS WITH NICKS OR BENDS WHERE DAMAGE IS MORE THAN AREA
BENDS ARE NOT PERMITTED.
BLADE STRAIGHTNESS INSPECTION REQURIEMENTS:
1.
SET A 1" LONG GAUGE BLOCK (HEIGHT AND WIDTH OF BLOCK OPTIONAL) 0.125" IN FROM THE TRAILING EDGE.
2.
USING A 0.062" WIDE FEELER GAGE 0.010" THICK AS NO-GO GAUGE. VERIFY IT CANNOT BE INSERTED BETWEEN THE BLADE AND BLOCKANYWHERE ALONG THE LENGTH OF THE BLADE IN THE REGION DEFINED IN FIGURE 601 .
3.
IF THE FEELER GAGE CAN BE INSERTED, REPLACE THE TURBINE HUB.
Ram Air Turbine (RAT) Inspection
Figure 601 (Sheet 2)
IS NOT PERMITTED.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-21-01
ALL ú ú 01 Page 603 ú Mar 20/94
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 液压 CHAPTER 29 - HYDRAULIC POWER 2(79)