S 422-013
(5)
Put the limit switch and the switch cover in the hole in the RAT strut housing.
S 422-014
(6)
Install the screws and washers which attach the switch cover to the RAT strut housing.
S 432-015
(7)
Tighten the screws by hand until you adjust the switch.
S 432-017
(8)
If the limit switch does not have inline electrical connectors, do this step:
(a) Install the electrical connectors on the wires in the wire harness and on the limit switch.
S 432-018
(9) Connect the wires from the limit switch to the electrical connectors on the wire harness.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-21-21
ALL ú ú 01 Page 204 ú Dec 20/90
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757 MAINTENANCE MANUAL
S 432-019
(10)
Install the heat-shrink tubing on the electrical connectors.
S 832-020
(11)
Do the Limit Switch Adjustment.
S 622-021
(12)
Apply the sealant on the electrical leads on the limit switch.
S 862-022
(13)
Retract the RAT (AMM 29-21-00/201).
TASK 29-21-21-832-023
4. Limit Switch Adjustment_______________________
A. Equipment
(1) Protractor - Commercially Available
B. References
(1)
AMM 29-21-00/201, Ram Air Turbine (RAT) System
(2)
AMM 29-21-05/401, Ram Air Turbine (RAT) Deployment Actuator
(3)
AMM 29-21-10/401, Ram Air Turbine (RAT) Door Actuator Link
C. Access
(1)
Location Zones 198 Wing to Body - Aft Lower Half (Right)
(2)
Access Panel
198MR RAT Compartment
D. Adjust the Limit Switch (Fig. 201)
S 862-024
(1)
If it is not in the extended position, extend the RAT (AMM 29-21-00/201).
S 032-025
(2)
Disconnect the lower end of the RAT deployment arm from the RAT strut housing (AMM 29-21-05/401).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-21-21
ALL ú ú 01 Page 205 ú May 28/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL
S 032-026
(3)
Disconnect the RAT door link from the door or from the RAT strut housing (AMM 29-21-10/401).
S 032-027
(4)
Disconnect the electrical connector at the top of the RAT strut housing, on the aft side.
S 982-028
(5)
Push on the end of the hydraulic pump to move the RAT in the direction of the retracted position.
S 222-029
(6)
Make sure the limit switch closes when the RAT strut housing is 13 | 1/2 degrees from the fully extended position.
NOTE: Do a check for continuity, between the electrical
____ connector pins 5 and 7, to find when the switch closes.
S 822-030
(7) If it is necessary, do these steps to adjust the limit switch:
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 液压 CHAPTER 29 - HYDRAULIC POWER 2(115)