S 422-013
 (5)  
Put the limit switch and the switch cover in the hole in the RAT strut housing.
S 422-014
 (6)  
Install the screws and washers which attach the switch cover to the RAT strut housing.
S 432-015
 (7)  
Tighten the screws by hand until you adjust the switch.
S 432-017
 (8)  
If the limit switch does not have inline electrical connectors, do this step:
 (a)  Install the electrical connectors on the wires in the wire harness and on the limit switch.
 S 432-018
 (9)  Connect the wires from the limit switch to the electrical connectors on the wire harness.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 29-21-21
 ALL  ú ú 01 Page 204 ú Dec 20/90 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A
757 MAINTENANCE MANUAL
 S 432-019
 (10)
 Install the heat-shrink tubing on the electrical connectors.
S 832-020
 (11)
 Do the Limit Switch Adjustment.
S 622-021
 (12)
 Apply the sealant on the electrical leads on the limit switch.
S 862-022
 (13)
 Retract the RAT (AMM 29-21-00/201).
 TASK 29-21-21-832-023
 4.  Limit Switch Adjustment_______________________
 A. Equipment
 (1)  Protractor - Commercially Available
 B. References
 (1)  
AMM 29-21-00/201, Ram Air Turbine (RAT) System
 (2)  
AMM 29-21-05/401, Ram Air Turbine (RAT) Deployment Actuator
 (3)  
AMM 29-21-10/401, Ram Air Turbine (RAT) Door Actuator Link
 C. Access
 (1)  
Location Zones 198 Wing to Body - Aft Lower Half (Right)
 (2)  
Access Panel
 198MR RAT Compartment
 D. Adjust the Limit Switch (Fig. 201)
 S 862-024
 (1)  
If it is not in the extended position, extend the RAT (AMM 29-21-00/201).
S 032-025
 (2)  
Disconnect the lower end of the RAT deployment arm from the RAT strut housing (AMM 29-21-05/401).
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 29-21-21
 ALL  ú ú 01 Page 205 ú May 28/99 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A
757 
MAINTENANCE MANUAL
 S 032-026
 (3)  
Disconnect the RAT door link from the door or from the RAT strut housing (AMM 29-21-10/401).
S 032-027
 (4)  
Disconnect the electrical connector at the top of the RAT strut housing, on the aft side.
S 982-028
 (5)  
Push on the end of the hydraulic pump to move the RAT in the direction of the retracted position.
S 222-029
 (6)  
Make sure the limit switch closes when the RAT strut housing is 13 | 1/2 degrees from the fully extended position.
 NOTE: Do a check for continuity, between the electrical
____ connector pins 5 and 7, to find when the switch closes.
 S 822-030
 (7)  If it is necessary, do these steps to adjust the limit switch:
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 液压 CHAPTER 29 - HYDRAULIC POWER 2(115)