S 032-004
 (3) 
Remove the lockwire and the nut on the limit switch.
 (4) 
Remove the limit switch.
 S 022-005
 TASK 29-21-17-422-006
 3.  Install the Limit Switch for the Ram Air Turbine (RAT)______________________________________________________
 A.  References
 (1) AMM 29-21-00/201, Ram Air Turbine (RAT) System
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 29-21-17
 ALL  ú ú 01 Page 201 ú May 28/99 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A
757 
MAINTENANCE MANUAL
LIMIT SWITCH FOR THE STOWED POSITION OF THE RAT 
SEE  B  
ASEE RAM AIR TURBINE (RAT)  ARM WHICH OPERATES THE LIMIT SWITCH 
RAT STRUT  
HOUSING  
DIMENSION "A"  
BRACKET  
LIMIT  
SWITCH  NUT  LOCKWASHER  
FWD  
PLUNGER  
SUPPORT  RAM AIR TURBINE (RAT)  
BRACKET (REF)  
A  
WIRE BUNDLE  
FWD  
LIMIT SWITCH  
B  
Limit Switch Installation  
Figure 201 
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 29-21-17
 ALL  ú ú 01 Page 202 ú May 28/99 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A
757 
MAINTENANCE MANUAL
 B. Access
 (1)  
Location Zones 198 Wing to Body - Aft Lower Half (Right)
 (2)  
Access Panel
 198MR RAT Compartment
 C. Install the Limit Switch (Fig. 201)
 S 822-007
 (1) 
Hold the limit switch in the bracket.
S 432-008
 (2) 
Install the nuts and tighten them by hand.
S 432-009
 (3) 
Connect the electrical wires at the splice.
S 832-010
 (4) 
Do the adjustment procedure for the limit switch.
S 862-011
 (5) 
Retract the RAT (AMM 29-21-00/201).
 TASK 29-21-17-832-012
 4. Adjustment for the Limit Switch
_______________________________
 A. References
 (1) 
AMM 24-22-00/201, Electrical Power - Control
 (2) 
AMM 29-21-00/201, Ram Air Turbine (RAT) System
 (3) 
AMM 29-21-10/401, Ram Air Turbine (RAT) Door Actuation Link
 B. Access
 (1)  
Location Zones 198 Wing to Body - Aft Lower Half (Right) 211/212 Control Cabin
 (2)  
Access Panel
 198MR RAT Compartment
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 29-21-17
 ALL  ú ú 01 Page 203 ú May 28/99 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A
757 MAINTENANCE MANUAL
 C. Adjust the Limit Switch (Fig. 201)
 S 862-013
 (1)  
Supply electrical power (AMM 24-22-00/201).
S 862-014 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:757 AMM 飞机维护手册 液压 CHAPTER 29 - HYDRAULIC POWER 2(101)