• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-10-11 13:08来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 29-32-00
 ALL  ú ú 01 Page 501 ú May 28/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

757
MAINTENANCE MANUAL

 S 015-004
 WARNING: USE THE PROCEDURE IN AMM 32-00-15/201 TO INSTALL THE DOOR
_______ LOCKS. THE DOORS OPEN AND CLOSE QUICKLY AND CAN CAUSE INJURY TO PERSONS OR DAMAGE TO EQUIPMENT.
 (3)  Open the doors for the landing gear and install the door locks (AMM 32-00-15/201).
 S 865-005
 WARNING: DO THE THRUST REVERSER DEACTIVATION PROCEDURE TO PREVENT THE
_______ OPERATION OF THE THRUST REVERSER. THE ACCIDENTAL OPERATION OF THE THRUST REVERSER CAN CAUSE INJURY TO PERSONS OR DAMAGE TO EQUIPMENT.
 (4)  
Do this procedure: Thrust Reverser Deactivation for Ground Maintenance (AMM 78-31-00/201).

 S 015-006

 (5)  
Open the access panels for the hydraulic bay in the left and right aft struts (AMM 06-43-00/201).

 S 015-008

 (6)  
Open the access panel for the central hydraulic service center (AMM 06-41-00/201).

 S 865-057

 (7)  
Make sure these circuit breakers on the overhead panel, P11 are closed:


 (a)  EICAS (6 locations)
 S 865-058
 (8)  Open these circuit breakers on the P11 panel and attach DO-NOT-CLOSE tags:
 (a)  11P1, L IND LTS 1
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-32-00
 ALL  ú ú 01 Page 502 ú May 28/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

757 MAINTENANCE MANUAL
 (b) 11P28, R IND LTS 1
 D. Do the System Test of the Overheat Lights for the Hydraulic Pumps
 (1)  S 035-059Disconnect the electrical connectors for the temperature switches from the left, right, and center alternating current motor pumps (ACMPS).
 (2)  S 495-060Connect a jumper between the pins 1 and 3 on each of the ACMP connectors.
 (3)  S 035-061Disconnect the electrical connector from the temperature switch on the left and right pressure/case drain filter modules for the engine-driven pumps (EDPs).
 (4)  S 495-062Connect a jumper between the pins 1 and 2 of the electrical connector for the temperature switch on each EDP filter module.
 (5)  S 865-063Remove the DO-NOT-CLOSE tags and close these circuit breakers on the P11 panel. (a) 11P1, L IND LTS 1 (b) 11P28, R IND LTS 1
 (6)  S 215-064Make sure these lights on the hydraulic control panel come on: (a) L ENG OVHT and L ELEC OVHT. (b) C1 ELEC OVHT and C2 ELEC OVHT. (c) R ENG OVHT and R ELEC OVHT.
 (7)  S 215-065Make sure these messages show on the EICAS: (a) L ELEC HYD OVHT and R ELEC HYD OVHT

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-32-00
 ALL  ú ú 01 Page 503 ú Dec 20/90
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

757
MAINTENANCE MANUAL

 (b) (c)  C HYD 1 OVHT and C HYD 2 OVHTL ENG HYD OVHT and R ENG HYD OVHT
 (8)  S 865-009Open this circuit breaker on the P11 panel and attach a DO-NOT-CLOSE tag: (a) R IND LTS 1
 (9)  S 095-010Remove the jumper from the pins 1 and 3 of the electrical connector for the left ACMP.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 液压 CHAPTER 29 - HYDRAULIC POWER 2(165)