C. Remove the Limit Switch (Fig. 201)
S 862-002
(1)
Extend the RAT (AMM 29-21-00/201).
S 022-003
(2)
Remove the screws that attach the limit switch to the switch support bracket.
S 022-004
(3)
Remove the limit switch and the switch plate from the switch support bracket.
S 032-005
(4)
If the switch has inline electrical connectors,
do these steps:
(a) Cut the heat-shrink tube from the inline electrical connectors.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-21-20
ALL ú ú 01 Page 201 ú May 28/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL
OUTBOARD SWIVEL VALVE
DEPLOYMENT SEE B
ACTUATOR
DOOR LINK
RAM AIR RAT STRUTTURBINE HOUSING(RAT)
SEE A
RAT
COMPARTMENT
DOOR
FWD INBD
RAM AIR TURBINE (RAT)
OUTBOARD SWIVEL VALVE
A
OUTBOARD SWIVEL VALVE
OUTBD FWD
ELECTRICAL STRUT
CONNECTOR
POSITION
LIMIT SWITCH
RAT STRUT SEE D E
HOUSING
FWD OUTBD SEE C
HOUSING
OUTBOARD SWIVEL VALVE
B
RAT STRUT HOUSING
C
RAT Strut Position Limit Switch Installation
Figure 201 (Sheet 1)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-21-20
ALL ú ú 01 Page 202 ú May 28/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL
OUTBOARD SWIVEL VALVE
STRUT POSITION LIMIT SWITCH
1
AIRPLANES WITH INLINE
E
ELECTRICAL CONNECTORS
RAT Strut Position Limit Switch Installation Figure 201 (Sheet 2)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-21-20
ALL ú ú 01 Page 203 ú May 28/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757 MAINTENANCE MANUAL
(b) Disconnect the inline electrical connectors.
S 032-006
(5) If the limit switch does not have inline electrical connectors, do these steps:
(a)
Cut the wire from the switch terminal C, approximately 3.25 inches from the limit switch.
(b)
Cut the wire from the switch terminal NC, approximately 5 inches from the limit switch.
TASK 29-21-20-422-007
3. Install the Limit Switch for the Ram Air Turbine (RAT)______________________________________________________
A. References
(1)
AMM 29-21-00/201, Ram Air Turbine (RAT) System
B.
Access
(1)
Location Zones 198 Wing to Body - Aft Lower Half (Right)
(2)
Access Panel
198MR RAT Compartment
C.
Install the Limit Switch (Fig. 201)