S 215-017
 (14)
 Make sure the L (R) SYS PRESS and the L (R) ENG PRESS lights go off when the system pressure is between 1300-1800 psi.
S 865-018
 (15)
 Push the ELEC/HYD switch on the EICAS maintenance panel on the right side panel, P61.
S 215-019
 (16)
 Make sure the pressure shown on EICAS for the left (right) hydraulic system is the same as the pressure on the service cart (+/- 150 psi).
S 215-020
 (17)
 Make sure the L (R) HYD SYS PRESS message is not shown on EICAS.
S 215-021
 (18)
 Make sure the L (R) HYD ELEC PUMP message is shown on EICAS.
S 865-022
 (19)
 Slowly decrease the pressure in the left (right) hydraulic system to 1200 +/- 150 psi.
S 215-023
 (20)
 Make sure the L (R) SYS PRESS and the L (R) ENG PRESS lights are on.
S 865-024
 (21)
 For the right hydraulic system, push the RESERVE BRAKE switch on the captains main instrument panel, P1, to ON.
 NOTE: This isolates the time delay for the right system indication
____
 from reserve brake circuits.
 S 865-025
 (22) Open this circuit breaker on the P11 panel:
 (a) 11A34, IND LIGHTS 3
 S 215-026
 (23)
 Make sure the L (R) SYS PRESS light on the hydraulic control panel goes off.
S 865-027
 (24)
 Close this circuit breaker on the P11 panel:
 (a) 11A34, IND LIGHTS 3
 S 215-028
 (25) Make sure the L (R) SYS PRESS light on the hydraulic control panel comes on after 2 seconds.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 29-31-00
 ALL  ú ú 01 Page 503 ú May 28/99 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A 
757 
MAINTENANCE MANUAL
 S 865-029
 (26)
 For the right hydraulic system, push the RESERVE BRAKE switch on the P1 panel to OFF.
S 865-030
 (27)
 Increase the pressure in the left (right) hydraulic system to 3000 psi.
S 865-031
 (28)
 Push the ELEC/HYD and then the AUTO-EVENT READ switches on the EICAS maintenance panel on the P61 panel. Push and hold the ERASE switch for approximately three seconds.
S 215-032
 (29)
 Make sure the L (R) HYD SYS MAINT message is not shown on EICAS.
S 865-033
 (30)
 Decrease the pressure in the left (right) hydraulic system to 2750 psi.
S 215-034
 (31)
 Make sure the L (R) HYD SYS MAINT message is shown on EICAS after approximately 60 seconds.
S 865-083
 (32)
 Increase the pressure in the left (right) hydraulic system to 3000 psi.
S 865-035
 (33)
 Push the ELEC/HYD and then the AUTO-EVENT READ switches on the EICAS maintenance panel on the P61 panel. Push and hold the ERASE switch for approximately three seconds.
S 215-036
 (34)
 Make sure the L (R) HYD SYS MAINT message is not shown on EICAS.
S 865-037
 (35)
 Put back the engine shutdown inhibit in the EICAS computers (AMM 31-41-00/201).
 (36)
 Decrease the pressure in the left (right) hydraulic system to zero.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 液压 CHAPTER 29 - HYDRAULIC POWER 2(155)