• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-10-11 13:08来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

INDICATOR - RESERVOIR FILL, N29  -- 1  197KL, AFT LEFT WING-TO-BODY FAIRING 29-18-03 
MODULE - RESERVOIR FILL FILTER -- 1  197KL, AFT LEFT WING-TO-BODY FAIRING 29-18-04 
PUMP - RESERVOIR MANUAL FILL  -- 1  197KL, AFT LEFT WING-TO-BODY FAIRING  29-18-01 
SWITCH - HYDRAULIC QUANTITY SELECT, S341 TRANSMITTER - (REF 29-33-00, FIG. 101) UNIT - (REF 29-33-00, FIG. 101) HYDRAULIC FLUID QUANTITY MONITOR, M122 SYS R, M340 SYS L, M338 SYS C, M339 HYDRAULIC FLUID QUANTITY  -- 1  197KL, AFT LEFT WING-TO-BODY FAIRING, RESERVOIR FILL SELECTOR VALVE * 
VALVE - RESERVOIR FILL SELECTOR  -- 1  197KL, AFT LEFT WING-TO-BODY FAIRING 29-18-02 

* SEE THE WDM EQUIPMENT LIST
Ground Servicing System - Component Index
Figure 101

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-18-00
 ALL  ú
 ú  01  Page 101
 ú  Jun 20/91 

BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

757 FAULT ISOLATION/MAINT MANUAL
OVERHEAD CIRCUIT
BREAKER PANEL, P11

FWD ACCESS PANEL, 197KL, FOR THE
FLIGHT COMPARTMENT
CENTRAL HYDRAULIC SERVICE CENTER
SUCTION HOSE  SEE  A 
(REF)  MANUAL PUMP TO 
FILL THE RESERVOIR  AFT LEFT WING-TO-BODY FAIRING 
INDICATOR, N29,  FILTER MODULE 
FOR RESERVOIR FILL  FOR RESERVOIR FILL 

SELECTOR VALVE FOR RESERVOIR FILL AND HYDRAULIC SELECT SWITCH, S341
PUMP HANDLE (REF)
PRESSURE FILL CONNECTION
OUTBD
ACCESS PANEL, 197KL FWD CENTRAL HYDRAULIC SERVICE CENTER
A
Ground Servicing System - Component Location Figure 102
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-18-00
 ALL  ú ú 01 Page 102 ú Jun 20/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757 MAINTENANCE MANUAL
 RESERVOIR MANUAL FILL PUMP - REMOVAL/INSTALLATION
_________________________________________________
 1.  General_______
 A.  This procedure contains two tasks. One task removes the manual fill pump for the hydraulic reservoirs. The other task installs the manual fill pump for the hydraulic reservoirs.
 TASK 29-18-01-024-001
 2.  Remove the Manual Fill Pump for the Reservoir_____________________________________________
 A.  References
 (1)  
AMM 06-41-00/201, Fuselage Access Doors and Panels

 (2)  
AMM 29-11-00/201, Main (Left, Right, and Center) Hydraulic Systems


 B.  Access
 (1)  
Location Zones
 197 Wing to Body - Aft Lower Half (Left)


 (2)  
Access Panel
 197KL Central Hydraulic Service Center

 

 C.  Remove the Manual Fill Pump (Fig. 401)
 S 014-002
 (1)  
Open the access door for the hydraulic service bay, 197KL (AMM 06-41-00/201).

 S 864-003

 (2)  
Remove the pressure from the hydraulic systems and the reservoirs (AMM 29-11-00/201)

 S 034-004

 (3)
Disconnect the inlet and outlet lines from the manual fill pump.

 S 494-005

 (4)  
Install caps on the hydraulic lines.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 液压 CHAPTER 29 - HYDRAULIC POWER 2(31)