S 865-151
 (43)
 Remove electrical power, if it is not necessary (AMM 24-22-00/201).
 TASK 29-21-00-735-213
 5.  Alternate System Test - RAT Hydraulic Pump and Drive System (Fig. 501)
___________________________________________________________
 NOTE: This procedure should only be used if a hydraulic cart is not
____
 available.
 A.  The following procedure may be used to operate both center ACMP's with a single electrical power source.
 NOTE: Usually, C2 ACMP will not operate with a single electrical
____ power source on the aircraft. This alternate procedure installs a temporary jumper in the control circuit to allow C2 ACMP to operate with a single electrical power source on the aircraft.
 S 865-157
 CAUTION: TO PREVENT POSSIBLE ELECTRICAL OVERLOAD, THE LEFT AND RIGHT
_______ HYDRUALIC SYSTEM ACMP'S MUST NOT BE OPERATED AT THE SAME TIME THE RAT IS BEING TESTED.
 (1) 
Select all 4 ACMP control switches to OFF.
S 865-208
 (2) 
Open and tag the following circuit breakers:
 (a) 
11K, ELEC HYD Control L
 (b) 
11K16, ELEC HYD PUMP Control R
 (3) 
Remove electrical power from airplane (AMM 24-22-00/201).
 S 865-209
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 29-21-00
 ALL  ú ú 08 Page 522 ú Sep 28/00 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A 
757 MAINTENANCE MANUAL
 S 015-214
 (4)  
Get access to the main equipment center through the electronics access door 119BL.
S 215-211
 (5)  
Locate the ELEC HYD C1 ELCU (M10006), on the P31 panel.
S 025-210
 (6)  
Remove D2934 connector from M10006 ELCU.
S 425-220
 (7)  
Install a suitable jumper between pins 5 and 6 on connectors D2934 at the M10006 ELCU. The jumper, consisting of a short wiring harness to be installed beteen connector D2943 and the M10006 ELCU, can be assembled as follows:
 Assemble a jumper harness of appropriate length using equivalent connetors and wires to match gage material and location of existing harness, except connect locations 5 and 6 (on the back side of the connector that will mate to D2934, pins 5 and 6) with an appropriate wire.
 S 865-215
 (8) Supply electrical power to the airplane (AMM 24-22-00/201).
 TASK 29-21-00-735-216
 6. Continue with the RAT system test:
 A. General
 CAUTION: DO NOT OPERATE THE LEFT OR RIGHT ACMP DURING RAT SYSTEM SPIN-UP
_______
 TEST.
 (1)  Obey this CAUTION for the following steps:
 B. Equipment
 (1)  
RAT Safety Screen - B29001-42
 (2)  
RAT Safety Screen Adapter - B29001-23
 (Necessary when lifting fixture - A71015 is
 used).
 ú  (3) Lifting Fixture - A71015-87; Hein-Werner Model 74; or Black Hawk Model 67554
 (4)  
Lifting Fixture - PM 81782/B
 (5)  
RAT Circuit Breaker Lock Set - B27065-9 or
 Equivalent
 (6)  
Stroboscopes (optional):
 (a)  Digital Stroboscope - Type 4913
 Bruel and Kjaer Instruments, Inc.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 液压 CHAPTER 29 - HYDRAULIC POWER 2(63)