(10)
 Connect the electrical connector to the left ACMP.
S 865-012
 (11)
 Remove the DO-NOT-CLOSE tag and close this circuit breaker on the P11 panel:
 (a) R IND LT
 S 215-013
 (12)
 Make sure the L ELEC HYD OVHT message does not show on the EICAS.
S 215-014
 (13)
 Make sure the L ELEC OVHT light on the hydraulic control panel is not on.
S 865-015
 (14)
 Open this circuit breaker on the P11 panel and attach a DO-NOT-CLOSE tag:
 (a) L IND LTS 1
 S 095-016
 (15) Remove the jumper from the pins 1 and 3 of the electrical connector for the right ACMP.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 29-32-00
 ALL  ú ú 01 Page 504 ú Jun 20/90 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A 
757 
MAINTENANCE MANUAL
 S 435-017
 (16)
 Connect the electrical connector to the right ACMP.
S 865-018
 (17)
 Remove the DO-NOT-CLOSE tag and close this circuit breaker on the P11 panel:
 (a) L IND LTS 1
 S 215-019
 (18)
 Make sure the R ELEC HYD OVHT message does not show on the EICAS.
S 215-020
 (19)
 Make sure the R ELEC OVHT light on the hydraulic control panel is not on.
S 865-021
 (20)
 Open this circuit breaker on the P11 panel and attach a DO-NOT-CLOSE tag:
 (a) R IND LTS 1
 S 095-022
 (21)
 Remove the jumper from the pins 1 and 3 of the electrical connector for the center ACMP C1.
S 435-023
 (22)
 Connect the electrical connector to the center ACMP C1.
S 865-024
 (23)
 Remove the DO-NOT-CLOSE tag and close this circuit breaker on the P11 panel:
 (a) R IND LTS 1
 S 215-025
 (24)
 Make sure the C HYD 1 OVHT message does not show on the EICAS.
S 215-026
 (25)
 Make sure the C1 ELEC OVHT light on the hydraulic control panel is not on.
S 865-027
 (26)
 Open this circuit breaker on the P11 panel and attach a DO-NOT-CLOSE tag:
 (a) L IND LTS 1
 S 095-028
 (27)
 Remove the jumper from the pins 1 and 3 of the electrical connector for the center ACMP C2.
 (28)
 Connect the electrical connector to the center ACMP C2.
 S 435-029
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 29-32-00
 ALL  ú ú 01 Page 505 ú Sep 20/94 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A
757 
MAINTENANCE MANUAL
 S 865-030
 (29) Remove the DO-NOT-CLOSE tag and close this circuit breaker on the P11 panel:
 (a) L IND LTS 1
 S 215-031
 (30)
 Make sure the C HYD 2 OVHT message does not show on the EICAS.
S 215-032
 (31)
 Make sure the C2 ELEC OVHT light on the hydraulic control panel is not on.
S 865-033
 (32)
 Open this circuit breaker on the P11 panel and attach a DO-NOT-CLOSE tag:
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 液压 CHAPTER 29 - HYDRAULIC POWER 2(166)