S 422-009
 (2)  
Put the switch plate on the inboard side of the switch support bracket.
S 422-010
 (3)  
Install the screws and washers to attach the limit switch to the support bracket.
 (4) 
Tighten the screws by hand until you adjust the limit switch.
 S 432-011
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 29-21-20
 ALL  ú ú 01 Page 204 ú May 28/99 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A
757 
MAINTENANCE MANUAL
 S 432-012
 (5)  If the limit switch does not have inline electrical connectors, do this step:
 (a)  Install the electrical connectors on the wires in the wire harness and on the limit switch.
 S 432-013
 (6)  
Connect the wires from the limit switch to the electrical connectors on the wire harness.
S 432-014
 (7) 
Install the heat-shrink tubing on the electrical connectors.
S 832-015
 (8)  
Do the Limit Switch Adjustment.
S 862-016
 (9)  
Retract the RAT (AMM 29-21-00/201).
 TASK 29-21-20-832-028
 4. Limit Switch Adjustment
_______________________
 A. Equipment
 (1)  Protractor - Commercially Available
 B. References
 (1)  
AMM 29-21-00/201, Ram Air Turbine (RAT) System
 (2)  
AMM 29-21-05/401, Ram Air Turbine (RAT) Deployment Actuator
 (3)  
AMM 29-21-10/401, Ram Air Turbine (RAT) Door Actuator Link
 C. Access
 (1)  
Location Zones
 198 Wing to Body - Aft Lower Half (Right)
 (2)  
Access Panel
 198MR RAT Compartment
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 29-21-20
 ALL  ú ú 01 Page 205 ú May 28/99 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A
757 MAINTENANCE MANUAL
 D. Adjust the Limit Switch (Fig. 201)
 S 862-017
 (1)  
If it is not in the extended position, extend the RAT
 (AMM 29-21-00/201).
 S 032-018
 (2)  
Disconnect the lower end of the RAT deployment arm from the RAT strut housing (AMM 29-21-05/401).
S 032-019
 (3)  
Disconnect the RAT door link from the RAT compartment door or from the RAT strut housing (AMM 29-21-10/401).
S 032-020
 (4)  
Disconnect the electrical connector at the top of the RAT strut housing, on the aft side.
S 982-021
 (5)  
Push on the end of the hydraulic pump to move the RAT in the direction of the retracted position.
S 222-022
 (6)  
Make sure the limit switch opens when the RAT strut housing is 15 | 1/2 degrees from the fully extended position.
 NOTE: You can do a check for continuity, between the electrical
____ connector pins 6 and 7, to find when the switch opens.
 S 822-023
 (7)  If it is necessary to adjust the limit switch, do the steps that follow:
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 液压 CHAPTER 29 - HYDRAULIC POWER 2(112)