Set the Cam (03-240A) to start to get a contact (0 VDC state to be read with test set-up) between the pin N and the pin L of the Connector (03-010).
5 Carefully tighten the Screws (03-250) at the torque value: 0,4 N.m (3.5403 lbf.in) to attach the Cam (03-240A).
6 Set the actuator to the Electrical Extended Position to read a ratio AB/AC = 0.902 + 0/- 0.010.
Page 7026
7 Set the Cam (03-210A) to start to get a contact (0 VDC state to be read with test set-up) between the pin J and the pin K of the Connector.
8 Tighten the Screws (03-220) at the torque value: 0,4 N.m (3.5403 lbf.in) to attach the Cam (03-210A).
(c) For Version DE:
1
Set the actuator to the Mechanical Stop Retracted position, mechanical stops in contact.
2 Make sure that the ratio AB/AC = 0.0634 + 0/- 0.0080.
3 Set the actuator to the Electrical Extended Position to read a ratio AB/AC = 0.673 + 0/- 0.020.
4 Set the Cam (03-210B) to start to get a contact (0 VDC state to be read with test set-up) between the pin N and the pin L of the Connector (03-010).
5 Carefully tighten the Screws (03-250) at the torque value: 0,4 N.m (3.5403 lbf.in) to attach the Cam (03-210B).
6 Set the actuator to the Electrical Retracted Position to read a ratio AB/AC = 0.0888 + 0/- 0.010.
7 Set the Cam (03-240B) to start to get a contact (0 VDC state to be read with test set-up) between the pin J and the pin K of the Connector.
8 Tighten the Screws (03-220) at the torque value: 0,4 N.m (3.5403 lbf.in) to attach the Cam (03-240B).
(d) Close-Up 1 De-energize the Electrical Test Set-Up. 2 Disconnect the Connector (03-010) from the Electrical Test Set-Up. 3 Remove the Screws (01-200), the Washers (01-220) and the applicable cover tool.
Subtask 21-53-12-440-009-A01
(14) Assembly of the Cover Assembly (01-190)
CAUTION: APPLY GREASE TYPE KRYTOX 240AZ TO THE GUIDE (01-220).
CAUTION: MAKE SURE THAT THE GROMMET (03-620) IS CORRECTLY SET TO THE COVER (01-260) BEFORE YOU INSTALL THE COVER TO THE PLATE ASSEMBLY.
(a)
If necessary, install the Inserts (01-280). NOTE: (refer to TASK 21-53-12-300-804-A01) to replace the Inserts (01-280).
(b)
If necessary, install the Bushes (01-260). NOTE: (refer to TASK 21-53-12-300-804-A01) to replace the Bushes (01-260).
(c)
If necessary, install the Identification Label (01-060) and the Pins (01-070).
Page 7027
21-53-12 JUN 15/10
(d) Install the Guide (01-230), the Washers (01-250) and the Screws (01-240) with locking compound (M14A) LOCTITE 222.