No specific  1  AC Voltmeter accuracy ± 0.2 % 
No specific  1  AC Power Supply 400 Hz, 115 V, 5 A max 
No specific  1  DC Power Supply 28 VDC / 1 A max (accuracy ± 0.2 V) 
No specific  1  Megohmmeter providing 45 to 500 VDC 
No specific  1  Milliohmmeter 0 to 100 m. ± 1.0 % of full scale (1 A) 
No specific  1  Ratiometer accuracy ± 0.2 % 
PHILIPS PM-3320A or equivalent  1  Digital Oscilloscope (recorder) 
09P2943  1  Load test bench (2500 N (562 lbf)) 
7M00576 (or equivalent) or No specific No specific No specific No specific  1 1 1  INTERTECHNIQUE electrical test bench electrical test bench that includes: - auto-transformer 600 VA power - three stable position, one-stage switch (SW1) - three stable position, two-stage switch (SW2) 

Page 1001
21-53-12  JUN 15/10
DESIGNATION  QTY  NAME 
No specific No specific No specific No specific No specific No specific No specific  2 1 1 1 1 3 4  - one-stable position, one-stage inverter (SW3, SW4) - AC Voltmeter - AC Ammeter - relay type LRE F250-14-1-1-A , 28 V, 950 . (RL) - resistor type RH10-1500 . (R) - zener diode DZX85C9 (Dz) - diode 1N4007 (D) 

(2)  Consumable Material 
Not Applicable 
(3)  Referenced Information 

REFERENCE  PAGE BLOCK  DESIGNATION 
(Ref. to Fig. 1001)  1001  ACTUATOR - ELECTRICAL TEST SET-UP 
(Ref. to Fig. 1002)  1001  VERSIONS ABC - FUNCTIONING OF ACTUATOR CONNECTED TO THE ELECTRICAL TEST SET-UP 
(Ref. to Fig. 1003)  1001  VERSIONS DE - FUNCTIONING OF ACTUATOR CONNECTED TO THE ELECTRICAL TEST SET-UP 
(Ref. to Fig. 1004)  1001  ACTUATOR - CASE BONDING TEST 
(Ref. to Fig. 1008)  1001  ACTUATOR - MECHANICAL INSTALLATION 
(Ref. to Fig. 1005)  1001  VERSIONS ABC - STROKES, MICROSWITCHES AND POTENTIOMETER TEST 
(Ref. to Fig. 1006)  1001  VERSIONS DE - STROKES, MICROSWITCHES AND POTENTIOMETER TEST 
(Ref. to Fig. 1007)  1001  ACTUATOR - LIMITS OF THE POTENTIOMETER SPIKE SPECIFIED SIGNAL 

Page 1002
21-53-12
C.  Job Set-Up Subtask 21-53-12-700-001-A01
(1) Test Conditions
(a) Do all tests under normal standard test laboratory ambient conditions:
-Ambient temperature: 25 ± 10 °C (77 ± 18 °F)
-Relative humidity: 85 % max
-Atmospheric pressure: from 846 to 1084 mb (12.27 to 15.72 psi)
Subtask 21-53-12-700-002-A01

(2) Electrical Test Set-Up
(a)  
 (Ref. to Fig. 1001) to connect the Electrical Test Set-Up to the Actuator.

(b)  
 (Ref. to Fig. 1002) to have the functioning of Actuator Versions ABC connected to the Electrical Test Set-Up.

(c)  
 (Ref. to Fig. 1003) to have the functioning of Actuator Versions DE connected to the Electrical Test Set-Up.


Page 1003
21-53-12  JUN 15/10
10 VDC

ACTUATOR - ELECTRICAL TEST SET-UP
Figure 1001/GRAPHIC 21-53-12-991-002-A01

Page 1004

SW3 (closed)
full

normal

t SW4 (open) full normal
t
door fully closed door flight closed
door flight open
door fully open

closed not closed

t

VERSIONS ABC - FUNCTIONING OF ACTUATOR CONNECTED TO THE ELECTRICAL TEST SET-UP
Figure 1002/GRAPHIC 21-53-12-991-003-A01

Page 1005
21-53-12 JUN 15/10
SW1
close
middle
open


t
SW3 (closed)
full
normal
t
SW4 (open)

full
normal
t
door fully open
door flight open
 