Page 1001
21-53-12 JUN 15/10
DESIGNATION QTY NAME
No specific No specific No specific No specific No specific No specific No specific 2 1 1 1 1 3 4 - one-stable position, one-stage inverter (SW3, SW4) - AC Voltmeter - AC Ammeter - relay type LRE F250-14-1-1-A , 28 V, 950 . (RL) - resistor type RH10-1500 . (R) - zener diode DZX85C9 (Dz) - diode 1N4007 (D)
(2) Consumable Material
Not Applicable
(3) Referenced Information
REFERENCE PAGE BLOCK DESIGNATION
(Ref. to Fig. 1001) 1001 ACTUATOR - ELECTRICAL TEST SET-UP
(Ref. to Fig. 1002) 1001 VERSIONS ABC - FUNCTIONING OF ACTUATOR CONNECTED TO THE ELECTRICAL TEST SET-UP
(Ref. to Fig. 1003) 1001 VERSIONS DE - FUNCTIONING OF ACTUATOR CONNECTED TO THE ELECTRICAL TEST SET-UP
(Ref. to Fig. 1004) 1001 ACTUATOR - CASE BONDING TEST
(Ref. to Fig. 1008) 1001 ACTUATOR - MECHANICAL INSTALLATION
(Ref. to Fig. 1005) 1001 VERSIONS ABC - STROKES, MICROSWITCHES AND POTENTIOMETER TEST
(Ref. to Fig. 1006) 1001 VERSIONS DE - STROKES, MICROSWITCHES AND POTENTIOMETER TEST
(Ref. to Fig. 1007) 1001 ACTUATOR - LIMITS OF THE POTENTIOMETER SPIKE SPECIFIED SIGNAL
Page 1002
21-53-12
C. Job Set-Up Subtask 21-53-12-700-001-A01
(1) Test Conditions
(a) Do all tests under normal standard test laboratory ambient conditions:
-Ambient temperature: 25 ± 10 °C (77 ± 18 °F)
-Relative humidity: 85 % max
-Atmospheric pressure: from 846 to 1084 mb (12.27 to 15.72 psi)
Subtask 21-53-12-700-002-A01
(2) Electrical Test Set-Up
(a)
(Ref. to Fig. 1001) to connect the Electrical Test Set-Up to the Actuator.
(b)
(Ref. to Fig. 1002) to have the functioning of Actuator Versions ABC connected to the Electrical Test Set-Up.
(c)
(Ref. to Fig. 1003) to have the functioning of Actuator Versions DE connected to the Electrical Test Set-Up.
Page 1003
21-53-12 JUN 15/10
10 VDC
ACTUATOR - ELECTRICAL TEST SET-UP
Figure 1001/GRAPHIC 21-53-12-991-002-A01
Page 1004
SW3 (closed)
full
normal
t SW4 (open) full normal
t
door fully closed door flight closed
door flight open
door fully open
closed not closed
t
VERSIONS ABC - FUNCTIONING OF ACTUATOR CONNECTED TO THE ELECTRICAL TEST SET-UP
Figure 1002/GRAPHIC 21-53-12-991-003-A01
Page 1005
21-53-12 JUN 15/10
SW1
close
middle
open
t
SW3 (closed)
full
normal
t
SW4 (open)
full
normal
t
door fully open
door flight open