SFCC 1
PPU DATE (DEG) DATE:XXX XX UTC:XXXX LH APPU FPPU RH APPU ***.* ***.* ***.* ***HEX ***HEX ***HEX ***
OTHER SFCC LH APPU FPPU RH APPU ***.* ***.* ***.* *** ***HEX ***HEX ***HEX
<RETURN PRINT>
Table 1 PPU DATA (DEG) displayed on the MCDU at the flap position FULL
R 1EFF : ALL 1 27-54-49Page 405 1 1 Aug 01/02 1 1 1CES 1
Subtask 27-54-49-020-063 R B. Preparation for Removal of the Flap Track 1 to 4 Actuators
(1) Hold the trailing edges of the inboard and outboard flaps on supports.
R (2) Use clamps to hold the flap carriages in position. NOTE : This is to make sure that the flap carriages do not move.
____
(3)
Measure and write down the dimension 'A' between the actuator lever and its stop face.
(4)
Remove the asymmetry-position pick-off unit from the flap track 4 actuator (Ref. TASK 27-51-18-000-001).
NOTE : The unit will be locked in the extended position and must not
____
be adjusted.
Subtask 27-54-49-020-062
C. Removal of the Flap Track 1 to 4 Actuators
(1) Remove the flap track 1 to 4 actuators in sequence (Ref. TASK 27-54-49-000-001), (Ref. TASK 27-54-49-000-002), (Ref. TASK 27-54-49-000-003) and (Ref. TASK 27-54-49-000-004).
TASK 27-54-49-400-005
Installation of the Flap Track 1 to 4 Actuators 6205CM(6255CM)/6211CM(6261CM)/ 6221CM(6271CM)/6233CM(6283CM)
WARNING : MAKE SURE THAT THE FLIGHT CONTROL SAFETY-LOCKS AND THE WARNING
_______ NOTICES ARE IN POSITION.
WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______ GEAR.
CAUTION : BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
_______
-
DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
-
DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
-MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific access platforms No specific safety barriers No specific warning notice
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power 27-50-00-866-008 Extension of the Flaps on the Ground 27-51-18-400-001 Installation of the Asymmetry-Position Pick-Off Unit
29CV (30CV) 27-54-00-710-001 Operational Test of the Flap System
1EFF : ALL 1 27-54-49Page 407 1 1 May 01/05R 1 1 1CES 1
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
27-54-49-400-001 Installation of the Flap Track 1 Actuator
6205CM(6255CM)
27-54-49-400-002 Installation of the Flap Track 2 Actuator
6211CM(6261CM)
27-54-49-400-003 Installation of the Flap Track 3 Actuator
6221CM(6271CM)
27-54-49-400-004 Installation of the Flap Track 4 Actuator
6233CM(6283CM) 27-60-00-866-002 Extension-Retraction of the Spoilers for Maintenance 31-32-00-860-006 Procedure to Get Access to the SYSTEM REPORT/TEST
F/CTL Page 32-00-00-481-001 Installation of the Safety Devices on the Landing
Gears
32-12-00-010-001 Open the Main Gear Doors for Access
32-12-00-410-001 Close the Main Gear Doors after Access
**ON A/C 001-049, 051-099, 101-149, 201-299,
27-54-49-991-008 Fig. 401
R **ON A/C 151-199, 401-499,
27-54-49-991-008-A Fig. 401A
**ON A/C 301-399,
27-54-49-991-008-B Fig. 401B
**ON A/C ALL
3. Job Set-up
__________
Subtask 27-54-49-941-077
A. Safety Precautions
WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE
_______ CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE.
(1)
Make sure that the safety barriers are in position.
(2)
Make sure that the warning notice are in position to tell persons not to operate the flaps.