R 1EFF : 159-199, 211-212, 1 27-54-55Page 450 1 1 Aug 01/05 1 1 1CES 1
R Subtask 27-54-55-420-061-C
R C. Installation of the Flap-Actuator Lever Assembly - Track 2
R WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL_______
R MATERIALS ONLY WITH A GOOD SUPPLY OF AIR.
R OBEY THE MANUFACTURERS INSTRUCTIONS.
R PUT ON PROTECTIVE CLOTHING.
R DO NOT GET THEM IN YOUR MOUTH.
R DO NOT SMOKE.
R DO NOT BREATHE THE GAS.
R THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT.
R GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.
R (1) At the track 2 position:
R (Ref. Fig. 402/TASK 27-54-55-991-004)
R (a) Apply SEALANTS (Material No. 09-018) to the bolts (43).
R (b) Install the bolts (43) in the outboard bracket (36) with the bolt
R heads inboard.
R (c) Apply SEALANTS (Material No. 09-018) or SEALANTS (Material No.
R 09-019) to the mating face of the anti-rotation plate (42).
R (d) Install the anti-rotation plate (42) on the bolts (43) and
R loosely install the nuts (41).
R (e) Apply SPECIAL MATERIALS (Material No. 05-064) to the holes of the
R bearing housings in the brackets (36).
R (f) Apply SEALANTS (Material No. 09-018) to the plain shank and
R flange of the bearing housing (34).
R (g) Install the bearing housing (34) in the outboard bracket (36) and
R tighten the nuts (41).
R (h) Apply COMMON GREASE (Material No. 04-022) to the ring nut (40).
R (i) Install the ring nut (40) on the bearing housing (34).
R (j) Torque the ring nut (40) with the SPANNER-FLAP LEVER TRACKS 2 AND
R 3 (98D27504028000) to between 1.4 and 1.5 m.daN (10.32 and 11.06
R lbf.ft).