-turn the actuator drive, as necessary, and engage the actuator drive into the flap drive lever
-install the torque limiter on the torque shaft (2).
(2)
Do these steps if the bolt holes of the actuator assembly and the structure do not align:
(a)
Move the torque limiter away from the torque shaft (2).
(b)
Put the universal joint (3) into the torque limiter.
(c)
Turn the universal joint (3) until the bolt holes are aligned.
(d)
Install the torque limiter on the torque shaft (2).
(e)
Remove the universal joint (3).
(3)
Put a countersunk washer (10) on a bolt (9), with the countersink
adjacent to the head of the bolt.
(4)
Install the bolt (9) with the countersunk washer (10), one or two (as applicable) of the washers (7) and one of the nuts (8) in the applicable hole (Ref. TASK 20-28-00-912-004):
-
FOR 6211CM
in the LH wing bonding position
-
FOR 6261CM
in the RH wing bonding position.
NOTE : Do not tighten in this step. Do not apply sealant.
____
(5)
Apply a layer of SEALANTS (Material No. 09-018) or SEALANTS (Material No. 09-019) to these remaining items:
-the shanks of the bolts (9) and (12).
(6)
Put the countersunk washers (10) on the bolts (9) and (12), with the countersink adjacent to the heads of the bolts.
(7)
Install the longer bolt (12) through the lever stop (11), the
structure and the actuator assembly.
(8)
Install the washer(s) (7) and the nut (8) on the longer bolt (12). Do not tighten in this step.
NOTE : You must install the same number of washers (7) that you
____
removed.
(9) Install the remaining bolts (9) through the actuator assembly and the structure.
(10)
Install two of the washers (7) and a nut (8) on each of the bolts (9). Do not tighten in this step.
(11)
TORQUE all the nuts (8) in a diagonally opposite sequence to between
2.8 and 3.0 m.daN (20.64 and 22.12 lbf.ft).
(12)
Do an electrical bonding check between the structure and the applicable bolt (Ref. TASK 20-28-00-869-002):
-
FOR 6211CM
in the LH wing bonding position
-
FOR 6261CM
R 1EFF : 001-049, 051-061, 101-105, 201-203, 1 27-54-49Page 470 1 1 May 01/05 1 1 1CES 1 in the RH wing bonding position.
(13)
Seal the bolt (9), the countersunk washer (10), the washer(s) (7) and the nut (8) installed in the applicable hole (Ref. TASK 20-28-00-912-004):
-
FOR 6211CM
in the LH wing bonding position
-
FOR 6261CM
in the RH wing bonding position.
(14)
Apply a layer of STORAGE PRESERVATION (Material No. 15-007) to these remaining items:
-
the bolts (9) and (12)
-
the washers (7) and (10)
-
the nuts (8).
(15)
Open the bottom of the two vent covers (13).
(16)
Put the 4 mm (0.1574 in.) dia. rod through the vent into each hole of the bearing to make sure the holes are not blocked.
(17)
Close the bottom vent cover (13).
(18)
Install the universal joint (3) and the torque shaft (4) (Ref. TASK 27-54-45-400-005):
-
FOR 6211CM
install 6210CM
-
FOR 6261CM
install 6260CM.
R **ON A/C 062-099, 106-149, 151-199, 204-299, 301-399, 401-499,
Subtask 27-54-49-420-068-A
C. Installation of the Flap Track 2 Actuator 6211CM(6261CM)
CAUTION : SUPPORT THE ACTUATOR, WHICH CAN WEIGH UP TO 10.5kg (23.2lbs).
_______ THIS WILL PREVENT DAMAGE TO THE RELATED STRUCTURE AND EQUIPMENT.
(1)
Do these steps together:
-turn the actuator drive, as necessary, and engage the actuator drive into the flap drive lever
-install the torque limiter on the torque shaft (2).
(2)
Do these steps if the bolt holes of the actuator assembly and the
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FLIGHT CONTROLS 飞行操纵5(115)